{"id":"CVE-2022-41772","aliases":["EUVD-2022-44943","GHSA-w68j-67vx-j26g"],"status":"published","title":"Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives...","description":"Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.","severity":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.25405,"percentile":0.97959,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-22"],"published":"2022-10-31T19:26:33Z","modified":"2026-06-17T05:03:48Z","products":[{"vendor":"delta electronics","product":"infrasuite device master"},{"vendor":"deltaww","product":"infrasuite_device_master"}],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07","tags":["government-resource","x_transferred","Patch","Third Party Advisory","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-41772"},{"url":"https://github.com/advisories/GHSA-w68j-67vx-j26g"}],"sources":{"cve":[{"id":"CVE-2022-41772","description":"\nDelta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution. \n\n","status":"published","published":"2022-10-31T19:26:33.695Z","modified":"2025-04-16T16:06:52.076Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"cna"}],"cwes":["CWE-22"],"updated_at":"2026-11-02T14:34:28.038197Z"}],"euvd":[{"id":"EUVD-2022-44943","description":"\nDelta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution. \n\n","status":"published","published":"2022-10-31T19:26:33Z","modified":"2025-04-16T16:06:52Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"updated_at":"2026-11-02T20:52:24.837818Z"}],"ghsa":[{"id":"GHSA-w68j-67vx-j26g","title":"Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives...","description":"Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.","status":"published","published":"2022-11-01T12:00:37Z","modified":"2023-01-31T05:04:09Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-22"],"updated_at":"2026-11-02T14:48:37.279982Z"}],"nvd":[{"id":"CVE-2022-41772","description":"\nDelta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution. \n\n","status":"published","published":"2022-10-31T20:15:13.603Z","modified":"2026-06-17T05:03:48.343Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"secondary"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"}],"cwes":["CWE-22"],"updated_at":"2026-11-02T14:07:31.127985Z"}]}}