{"id":"CVE-2022-43457","aliases":["EUVD-2022-46458","GHSA-57jq-6mm4-q8pw"],"status":"published","title":"Delta Electronics DIAEnergie SQL Injection","description":"SQL Injection in \n\n\n\n\n\n\n\n\n\n\n\nHandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network","severity":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-10","score":0.00691,"percentile":0.53154,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-89"],"published":"2022-11-17T22:45:54Z","modified":"2026-06-17T05:06:35Z","products":[{"vendor":"delta electronics","product":"diaenergie"},{"vendor":"deltaww","product":"diaenergie"}],"references":[{"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-06","tags":["x_transferred","Mitigation","Third Party Advisory","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-43457"},{"url":"https://github.com/advisories/GHSA-57jq-6mm4-q8pw"}],"sources":{"cve":[{"id":"CVE-2022-43457","title":"Delta Electronics DIAEnergie SQL Injection","description":"SQL Injection in \n\n\n\n\n\n\n\n\n\n\n\nHandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network","status":"published","published":"2022-11-17T22:45:54.782Z","modified":"2024-10-15T18:34:46.178Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"}],"cwes":["CWE-89"],"updated_at":"2026-11-02T14:34:25.308772Z"}],"euvd":[{"id":"EUVD-2022-46458","description":"SQL Injection in \n\n\n\n\n\n\n\n\n\n\n\nHandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network","status":"published","published":"2022-11-17T22:45:54Z","modified":"2024-10-15T18:34:46Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-03T00:27:36.689661Z"}],"ghsa":[{"id":"GHSA-57jq-6mm4-q8pw","title":"SQL Injection in HandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02...","description":"SQL Injection in HandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network","status":"published","published":"2022-11-18T00:30:18Z","modified":"2023-01-29T05:03:12Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-89"],"updated_at":"2026-11-02T14:45:16.184529Z"}],"nvd":[{"id":"CVE-2022-43457","description":"SQL Injection in \n\n\n\n\n\n\n\n\n\n\n\nHandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network","status":"published","published":"2022-11-17T23:15:24.203Z","modified":"2026-06-17T05:06:35.11Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"}],"cwes":["CWE-89"],"updated_at":"2026-11-02T14:07:32.395456Z"}]}}