{"id":"CVE-2022-44807","aliases":["EUVD-2022-47738","GHSA-rxv7-j96r-9mj5"],"status":"published","title":"D-Link DIR-882 1.10B02 and 1.20B06 is vulnerable to Buffer Overflow via webGetVarString.","description":"D-Link DIR-882 1.10B02 and 1.20B06 is vulnerable to Buffer Overflow via webGetVarString.","severity":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-09","score":0.01309,"percentile":0.70819,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-787"],"published":"2022-11-22T00:00:00Z","modified":"2026-06-17T05:08:57Z","products":[{"vendor":"dlink","product":"dir-882_firmware"}],"references":[{"url":"https://www.dlink.com/en/security-bulletin/","tags":["x_transferred","Vendor Advisory"]},{"url":"https://github.com/RobinWang825/IoT_vuln/tree/main/D-Link/DIR-882/5","tags":["x_transferred","Exploit","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2022-44807"},{"url":"https://www.dlink.com/en/security-bulletin"},{"url":"https://github.com/advisories/GHSA-rxv7-j96r-9mj5"}],"sources":{"cve":[{"id":"CVE-2022-44807","description":"D-Link DIR-882 1.10B02 and 1.20B06 is vulnerable to Buffer Overflow via webGetVarString.","status":"published","published":"2022-11-22T00:00:00Z","modified":"2025-04-29T19:36:01.161Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"adp"}],"cwes":["CWE-787"],"updated_at":"2026-11-02T14:34:30.176321Z"}],"euvd":[{"id":"EUVD-2022-47738","description":"D-Link DIR-882 1.10B02 and 1.20B06 is vulnerable to Buffer Overflow via webGetVarString.","status":"published","published":"2022-11-22T00:00:00Z","modified":"2025-04-29T19:36:01Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"updated_at":"2026-11-02T20:52:00.012701Z"}],"ghsa":[{"id":"GHSA-rxv7-j96r-9mj5","title":"D-Link DIR-882 1.10B02 and 1.20B06 is vulnerable to Buffer Overflow via webGetVarString.","description":"D-Link DIR-882 1.10B02 and 1.20B06 is vulnerable to Buffer Overflow via webGetVarString.","status":"published","published":"2022-11-22T15:30:25Z","modified":"2025-04-29T21:32:33Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-787"],"updated_at":"2026-11-02T15:02:04.142676Z"}],"nvd":[{"id":"CVE-2022-44807","description":"D-Link DIR-882 1.10B02 and 1.20B06 is vulnerable to Buffer Overflow via webGetVarString.","status":"published","published":"2022-11-22T15:15:13.613Z","modified":"2026-06-17T05:08:57.843Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"secondary"}],"cwes":["CWE-787"],"updated_at":"2026-11-02T14:07:32.395456Z"}]}}
