{"id":"CVE-2023-1009","aliases":["EUVD-2023-23301","GHSA-jcwr-vr95-x32m"],"status":"published","title":"DrayTek Vigor 2960 Web Management Interface mainfunction.cgi sub_1DF14 path traversal","description":"** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in DrayTek Vigor 2960 1.5.1.4/1.5.1.5. Affected is the function sub_1DF14 of the file /cgi-bin/mainfunction.cgi of the component Web Management Interface. The manipulation of the argument option with the input /../etc/passwd- leads to path traversal. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-221742 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.","severity":{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.15687,"percentile":0.96878,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-22"],"published":"2023-02-24T10:31:15Z","modified":"2026-06-17T05:26:53Z","products":[{"vendor":"draytek","product":"vigor 2960"},{"vendor":"draytek","product":"vigor2960_firmware"}],"references":[{"url":"https://vuldb.com/?id.221742","tags":["vdb-entry","technical-description","x_transferred","Third Party Advisory"]},{"url":"https://vuldb.com/?ctiid.221742","tags":["signature","permissions-required","x_transferred","Permissions Required"]},{"url":"https://github.com/xxy1126/Vuln/blob/main/Draytek/1.md","tags":["exploit","x_transferred","Exploit","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-1009"},{"url":"https://github.com/advisories/GHSA-jcwr-vr95-x32m"}],"sources":{"cve":[{"id":"CVE-2023-1009","title":"DrayTek Vigor 2960 Web Management Interface mainfunction.cgi sub_1DF14 path traversal","description":"** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in DrayTek Vigor 2960 1.5.1.4/1.5.1.5. Affected is the function sub_1DF14 of the file /cgi-bin/mainfunction.cgi of the component Web Management Interface. The manipulation of the argument option with the input /../etc/passwd- leads to path traversal. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-221742 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.","status":"published","published":"2023-02-24T10:31:15.666Z","modified":"2025-03-11T15:50:04.228Z","cvss":[{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"cna"},{"version":"3.0","score":6.5,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"cna"},{"version":"2.0","score":4,"vector":"AV:N/AC:L/Au:S/C:P/I:N/A:N","assessor":"cna"}],"cwes":["CWE-22"],"updated_at":"2026-11-02T14:35:31.657022Z"}],"euvd":[{"id":"EUVD-2023-23301","description":"** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in DrayTek Vigor 2960 1.5.1.4/1.5.1.5. Affected is the function sub_1DF14 of the file /cgi-bin/mainfunction.cgi of the component Web Management Interface. The manipulation of the argument option with the input /../etc/passwd- leads to path traversal. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-221742 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.","status":"published","published":"2023-02-24T10:31:15Z","modified":"2025-03-11T15:50:04Z","cvss":[{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","level":"medium"}],"updated_at":"2026-11-02T20:53:07.779422Z"}],"ghsa":[{"id":"GHSA-jcwr-vr95-x32m","title":"A vulnerability classified as problematic has been found in DrayTek Vigor 2960 1.5.1.4. Affected...","description":"A vulnerability classified as problematic has been found in DrayTek Vigor 2960 1.5.1.4. Affected is the function sub_1DF14 of the file /cgi-bin/mainfunction.cgi. The manipulation of the argument option with the input /../etc/password leads to path traversal. The attack needs to be done within the local network. The exploit has been disclosed to the public and may be used. VDB-221742 is the identifier assigned to this vulnerability.","status":"published","published":"2023-02-24T12:31:20Z","modified":"2023-03-14T05:06:36Z","cvss":[{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","level":"medium"}],"cwes":["CWE-22"],"updated_at":"2026-11-02T14:54:19.756427Z"}],"nvd":[{"id":"CVE-2023-1009","description":"** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in DrayTek Vigor 2960 1.5.1.4/1.5.1.5. Affected is the function sub_1DF14 of the file /cgi-bin/mainfunction.cgi of the component Web Management Interface. The manipulation of the argument option with the input /../etc/passwd- leads to path traversal. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-221742 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.","status":"published","published":"2023-02-24T11:15:10.997Z","modified":"2026-06-17T05:26:53.177Z","cvss":[{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"secondary"},{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"primary"},{"version":"2.0","score":4,"vector":"AV:N/AC:L/Au:S/C:P/I:N/A:N","level":"medium","assessor":"secondary"}],"cwes":["CWE-22"],"updated_at":"2026-11-02T14:07:47.623983Z"}]}}
