{"id":"CVE-2023-1049","aliases":["EUVD-2023-23340","GHSA-63c6-hm8j-v6m9"],"status":"published","title":"A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that...","description":"A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that\ncould cause execution of malicious code when an unsuspicious user loads a project file from the\nlocal filesystem into the HMI.","severity":{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-10","score":0.00597,"percentile":0.48916,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-94"],"published":"2023-06-14T07:27:59Z","modified":"2026-06-17T05:26:59Z","products":[{"vendor":"schneider electric","product":"ecostruxure™ operator terminal expert"},{"vendor":"schneider electric","product":"pro-face blue"},{"vendor":"schneider-electric","product":"ecostruxure_operator_terminal_expert"},{"vendor":"schneider-electric","product":"pro-face_blue"}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-164-01.pdf","tags":["x_transferred","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-1049"},{"url":"https://github.com/advisories/GHSA-63c6-hm8j-v6m9"}],"sources":{"cve":[{"id":"CVE-2023-1049","description":"\nA CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that\ncould cause execution of malicious code when an unsuspicious user loads a project file from the\nlocal filesystem into the HMI.\n\n","status":"published","published":"2023-06-14T07:27:59.794Z","modified":"2025-01-02T20:43:15.38Z","cvss":[{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"}],"cwes":["CWE-94"],"updated_at":"2026-11-02T14:35:32.376766Z"}],"euvd":[{"id":"EUVD-2023-23340","description":"\nA CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that\ncould cause execution of malicious code when an unsuspicious user loads a project file from the\nlocal filesystem into the HMI.\n\n","status":"published","published":"2023-06-14T07:27:59Z","modified":"2025-01-02T20:43:15Z","cvss":[{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-03T00:04:27.4378Z"}],"ghsa":[{"id":"GHSA-63c6-hm8j-v6m9","title":"\nA CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that...","description":"\nA CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that\ncould cause execution of malicious code when an unsuspicious user loads a project file from the\nlocal filesystem into the HMI.\n\n","status":"published","published":"2023-06-14T09:30:42Z","modified":"2024-04-04T04:49:33Z","cvss":[{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-94"],"updated_at":"2026-11-02T14:56:27.331112Z"}],"nvd":[{"id":"CVE-2023-1049","description":"\nA CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that\ncould cause execution of malicious code when an unsuspicious user loads a project file from the\nlocal filesystem into the HMI.\n\n","status":"published","published":"2023-06-14T08:15:08.773Z","modified":"2026-06-17T05:26:59.22Z","cvss":[{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"}],"cwes":["CWE-94"],"updated_at":"2026-11-02T14:08:06.335469Z"}]}}