{"id":"CVE-2023-1143","aliases":["EUVD-2023-23426","GHSA-839j-pmmv-f8m4"],"status":"published","title":"CVE-2023-1143","description":"In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code.","severity":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00835,"percentile":0.58139,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"published":"2023-03-27T14:46:20Z","modified":"2026-06-17T05:27:12Z","products":[{"vendor":"delta electronics","product":"infrasuite device master"},{"vendor":"deltaww","product":"infrasuite_device_master"}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02","tags":["x_transferred","Third Party Advisory","US Government Resource"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-1143"},{"url":"https://github.com/advisories/GHSA-839j-pmmv-f8m4"}],"sources":{"cve":[{"id":"CVE-2023-1143","title":"CVE-2023-1143","description":"In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code.","status":"published","published":"2023-03-27T14:46:20Z","modified":"2025-01-16T21:39:49.421Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"}],"updated_at":"2026-11-02T14:35:32.376766Z"}],"euvd":[{"id":"EUVD-2023-23426","description":"In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code.","status":"published","published":"2023-03-27T14:46:20Z","modified":"2025-01-16T21:39:49Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-03T00:04:17.573711Z"}],"ghsa":[{"id":"GHSA-839j-pmmv-f8m4","title":"In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua...","description":"In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code.","status":"published","published":"2023-03-27T15:30:17Z","modified":"2023-04-07T05:08:40Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-02T14:54:27.812339Z"}],"nvd":[{"id":"CVE-2023-1143","description":"In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code.","status":"published","published":"2023-03-27T15:15:08.08Z","modified":"2026-06-17T05:27:12.85Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"}],"updated_at":"2026-11-02T14:07:50.908252Z"}]}}