{"id":"CVE-2023-24146","aliases":["EUVD-2023-28209","GHSA-hw59-w5mg-cjph"],"status":"published","title":"TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the...","description":"TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the minute parameter in the setRebootScheCfg function.","severity":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-12","score":0.01915,"percentile":0.80139,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-77"],"published":"2023-02-03T00:00:00Z","modified":"2026-06-17T05:38:44Z","products":[{"vendor":"totolink","product":"ca300-poe_firmware"}],"references":[{"url":"https://github.com/Double-q1015/CVE-vulns/blob/main/totolink_ca300-poe/setRebootScheCfg_minute/setRebootScheCfg_minute.md","tags":["x_transferred","Exploit","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-24146"},{"url":"https://github.com/advisories/GHSA-hw59-w5mg-cjph"}],"sources":{"cve":[{"id":"CVE-2023-24146","description":"TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the minute parameter in the setRebootScheCfg function.","status":"published","published":"2023-02-03T00:00:00Z","modified":"2025-03-26T18:40:19.939Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"adp"}],"cwes":["CWE-77"],"updated_at":"2026-11-02T14:35:27.006218Z"}],"euvd":[{"id":"EUVD-2023-28209","description":"TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the minute parameter in the setRebootScheCfg function.","status":"published","published":"2023-02-03T00:00:00Z","modified":"2025-03-26T18:40:19Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"updated_at":"2026-11-02T20:52:50.922534Z"}],"ghsa":[{"id":"GHSA-hw59-w5mg-cjph","title":"TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the...","description":"TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the minute parameter in the setRebootScheCfg function.","status":"published","published":"2023-02-03T18:30:33Z","modified":"2023-02-18T05:05:36Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-77"],"updated_at":"2026-11-02T14:54:10.14247Z"}],"nvd":[{"id":"CVE-2023-24146","description":"TOTOLINK CA300-PoE V6.2c.884 was discovered to contain a command injection vulnerability via the minute parameter in the setRebootScheCfg function.","status":"published","published":"2023-02-03T16:15:12.943Z","modified":"2026-06-17T05:38:44.617Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"secondary"}],"cwes":["CWE-77"],"updated_at":"2026-11-02T14:07:46.064662Z"}]}}