{"id":"CVE-2023-27980","aliases":["EUVD-2023-31706","GHSA-7x8q-p6x2-5gq2"],"status":"published","title":"A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server...","description":"A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)","severity":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-10","score":0.00881,"percentile":0.59439,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-306"],"published":"2023-03-21T00:00:00Z","modified":"2026-06-17T05:46:18Z","products":[{"vendor":"schneider electric","product":"custom reports (rms16.dll)"},{"vendor":"schneider electric","product":"igss dashboard (dashboard.exe)"},{"vendor":"schneider electric","product":"igss data server(igssdataserver.exe)"},{"vendor":"schneider-electric","product":"custom_reports"},{"vendor":"schneider-electric","product":"igss_dashboard"},{"vendor":"schneider-electric","product":"igss_data_server"}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-073-04.pdf","tags":["x_transferred","Patch","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-27980"},{"url":"https://github.com/advisories/GHSA-7x8q-p6x2-5gq2"}],"sources":{"cve":[{"id":"CVE-2023-27980","description":"A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)","status":"published","published":"2023-03-21T00:00:00Z","modified":"2025-02-05T20:05:44.377Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"}],"cwes":["CWE-306"],"updated_at":"2026-11-02T14:35:26.63732Z"}],"euvd":[{"id":"EUVD-2023-31706","description":"A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)","status":"published","published":"2023-03-21T00:00:00Z","modified":"2025-02-05T20:05:44Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-03T00:04:04.235223Z"}],"ghsa":[{"id":"GHSA-7x8q-p6x2-5gq2","title":"A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server...","description":"A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)","status":"published","published":"2023-03-21T06:30:16Z","modified":"2023-04-01T05:07:09Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-306"],"updated_at":"2026-11-02T14:54:26.249885Z"}],"nvd":[{"id":"CVE-2023-27980","description":"A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)","status":"published","published":"2023-03-21T06:15:13.063Z","modified":"2026-06-17T05:46:18.18Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"}],"cwes":["CWE-306"],"updated_at":"2026-11-02T14:07:49.031498Z"}]}}
