{"id":"CVE-2023-28611","aliases":["EUVD-2023-32279","GHSA-9xmf-4p3w-hc8w"],"status":"published","title":"Incorrect authorization in OMICRON StationGuard 1.10 through 2.20 and StationScout 1.30 through 2...","description":"Incorrect authorization in OMICRON StationGuard 1.10 through 2.20 and StationScout 1.30 through 2.20 allows an attacker to bypass intended access restrictions.","severity":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-09","score":0.00645,"percentile":0.51214,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-863"],"published":"2023-03-23T00:00:00Z","modified":"2026-06-17T05:48:23Z","products":[{"vendor":"omicronenergy","product":"stationguard"},{"vendor":"omicronenergy","product":"stationscout"}],"references":[{"url":"https://www.omicronenergy.com/en/support/product-security/","tags":["x_transferred","Vendor Advisory"]},{"url":"https://www.omicronenergy.com/fileadmin/user_upload/website/files/product-security/osa-6.txt","tags":["x_transferred","Mitigation","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-28611"},{"url":"https://www.omicronenergy.com/en/support/product-security"},{"url":"https://github.com/advisories/GHSA-9xmf-4p3w-hc8w"}],"sources":{"cve":[{"id":"CVE-2023-28611","description":"Incorrect authorization in OMICRON StationGuard 1.10 through 2.20 and StationScout 1.30 through 2.20 allows an attacker to bypass intended access restrictions.","status":"published","published":"2023-03-23T00:00:00Z","modified":"2025-02-25T19:57:56.64Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"adp"}],"cwes":["CWE-863"],"updated_at":"2026-11-02T14:35:32.376766Z"}],"euvd":[{"id":"EUVD-2023-32279","description":"Incorrect authorization in OMICRON StationGuard 1.10 through 2.20 and StationScout 1.30 through 2.20 allows an attacker to bypass intended access restrictions.","status":"published","published":"2023-03-23T00:00:00Z","modified":"2025-02-25T19:57:56Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"updated_at":"2026-11-02T20:53:23.677257Z"}],"ghsa":[{"id":"GHSA-9xmf-4p3w-hc8w","title":"Incorrect authorization in OMICRON StationGuard 1.10 through 2.20 and StationScout 1.30 through 2...","description":"Incorrect authorization in OMICRON StationGuard 1.10 through 2.20 and StationScout 1.30 through 2.20 allows an attacker to bypass intended access restrictions.","status":"published","published":"2023-03-23T21:30:17Z","modified":"2025-02-25T21:32:27Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-863"],"updated_at":"2026-11-02T15:00:03.228993Z"}],"nvd":[{"id":"CVE-2023-28611","description":"Incorrect authorization in OMICRON StationGuard 1.10 through 2.20 and StationScout 1.30 through 2.20 allows an attacker to bypass intended access restrictions.","status":"published","published":"2023-03-23T21:15:20.377Z","modified":"2026-06-17T05:48:23.37Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"secondary"}],"cwes":["CWE-863"],"updated_at":"2026-11-02T14:07:50.908252Z"}]}}