{"id":"CVE-2023-39169","aliases":["EUVD-2023-42904","GHSA-fw57-89vj-7gfh"],"status":"published","title":"SENEC: Storage Box V1,V2 and V3 using default credentials","description":"The affected devices use publicly available default credentials with administrative privileges.","severity":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00898,"percentile":0.6004,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-1188","CWE-798"],"published":"2023-12-07T14:14:43Z","modified":"2026-06-17T06:11:40Z","products":[{"vendor":"enbw","product":"senec_storage_box_firmware"},{"vendor":"senec","product":"storage box v1"},{"vendor":"senec","product":"storage box v2"},{"vendor":"senec","product":"storage box v3"}],"references":[{"url":"https://seclists.org/fulldisclosure/2023/Nov/3","tags":["x_transferred","Mailing List","Not Applicable","Third Party Advisory"]},{"url":"http://seclists.org/fulldisclosure/2023/Nov/10"},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-39169"},{"url":"https://github.com/advisories/GHSA-fw57-89vj-7gfh"}],"sources":{"cve":[{"id":"CVE-2023-39169","title":"SENEC: Storage Box V1,V2 and V3 using default credentials","description":"The affected devices use publicly available default credentials with administrative privileges.","status":"published","published":"2023-12-07T14:14:43.336Z","modified":"2025-11-04T19:17:37.357Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"cna"}],"cwes":["CWE-798"],"updated_at":"2026-11-02T14:35:33.462059Z"}],"euvd":[{"id":"EUVD-2023-42904","description":"The affected devices use publicly available default credentials with administrative privileges.","status":"published","published":"2023-12-07T14:14:43Z","modified":"2025-11-04T19:17:37Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"updated_at":"2026-11-02T19:49:22.434386Z"}],"ghsa":[{"id":"GHSA-fw57-89vj-7gfh","title":"The affected devices use publicly available default credentials with administrative privileges.","description":"The affected devices use publicly available default credentials with administrative privileges.","status":"published","published":"2023-12-07T15:30:38Z","modified":"2025-11-04T21:30:50Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-798","CWE-1188"],"updated_at":"2026-11-02T15:04:36.009389Z"}],"nvd":[{"id":"CVE-2023-39169","description":"The affected devices use publicly available default credentials with administrative privileges.","status":"published","published":"2023-12-07T15:15:07.777Z","modified":"2026-06-17T06:11:40.157Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"secondary"}],"cwes":["CWE-798"],"updated_at":"2026-11-02T14:08:54.010507Z"}]}}