{"id":"CVE-2023-4152","aliases":["EUVD-2023-54032","GHSA-v7hg-r7jc-rmvp"],"status":"published","title":"Frauscher FDS101 for FAdC/FAdCi path traversal vulnerability","description":"Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.","severity":{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-08","score":0.00984,"percentile":0.62561,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-22"],"published":"2023-09-21T06:18:21Z","modified":"2026-06-17T06:37:11Z","products":[{"vendor":"frauscher","product":"fds101 for fadc/fadci"},{"vendor":"frauscher","product":"frauscher_diagnostic_system_101"}],"references":[{"url":"https://cert.vde.com/en/advisories/VDE-2023-038/","tags":["x_transferred","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-4152"},{"url":"https://cert.vde.com/en/advisories/VDE-2023-038"},{"url":"https://github.com/advisories/GHSA-v7hg-r7jc-rmvp"}],"sources":{"cve":[{"id":"CVE-2023-4152","title":"Frauscher FDS101 for FAdC/FAdCi path traversal vulnerability","description":"Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.\n","status":"published","published":"2023-09-21T06:18:21.444Z","modified":"2024-09-24T16:21:57.187Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"cna"}],"cwes":["CWE-22"],"updated_at":"2026-11-02T14:35:30.116696Z"}],"euvd":[{"id":"EUVD-2023-54032","description":"Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.\n","status":"published","published":"2023-09-21T06:18:21Z","modified":"2024-09-24T16:21:57Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high"}],"updated_at":"2026-11-03T00:28:15.323597Z"}],"ghsa":[{"id":"GHSA-v7hg-r7jc-rmvp","title":"Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are...","description":"Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.\n","status":"published","published":"2023-09-21T09:30:18Z","modified":"2024-04-04T07:47:22Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high"}],"cwes":["CWE-22"],"updated_at":"2026-11-02T14:56:54.849147Z"}],"nvd":[{"id":"CVE-2023-4152","description":"Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS101 device.\n","status":"published","published":"2023-09-21T07:15:14.3Z","modified":"2026-06-17T06:37:11.357Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"secondary"}],"cwes":["CWE-22"],"updated_at":"2026-11-02T14:08:29.595868Z"}]}}