{"id":"CVE-2023-4744","aliases":["EUVD-2023-54592","GHSA-qj82-g9mg-vp5w"],"status":"published","title":"Tenda AC8 formSetDeviceName stack-based overflow","description":"A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.","severity":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.01845,"percentile":0.79201,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-121","CWE-787"],"published":"2023-09-03T23:31:04Z","modified":"2026-06-17T06:38:30Z","products":[{"vendor":"tenda","product":"ac8"},{"vendor":"tenda","product":"ac8_firmware"}],"references":[{"url":"https://vuldb.com/?id.238633","tags":["vdb-entry","technical-description","x_transferred","Third Party Advisory"]},{"url":"https://vuldb.com/?ctiid.238633","tags":["signature","permissions-required","x_transferred","Third Party Advisory"]},{"url":"https://github.com/GleamingEyes/vul/blob/main/tenda_ac8/ac8_1.md","tags":["exploit","x_transferred","Exploit","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-4744"},{"url":"https://github.com/advisories/GHSA-qj82-g9mg-vp5w"}],"sources":{"cve":[{"id":"CVE-2023-4744","title":"Tenda AC8 formSetDeviceName stack-based overflow","description":"A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.","status":"published","published":"2023-09-03T23:31:04.502Z","modified":"2024-09-30T20:37:02.94Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"cna"},{"version":"3.0","score":9.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"cna"},{"version":"2.0","score":10,"vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","assessor":"cna"}],"cwes":["CWE-121"],"updated_at":"2026-11-02T14:35:30.851125Z"}],"euvd":[{"id":"EUVD-2023-54592","description":"A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.","status":"published","published":"2023-09-03T23:31:04Z","modified":"2024-09-30T20:37:02Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"updated_at":"2026-11-03T00:28:01.909154Z"}],"ghsa":[{"id":"GHSA-qj82-g9mg-vp5w","title":"A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical....","description":"A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.","status":"published","published":"2023-09-04T00:30:14Z","modified":"2023-11-05T05:04:46Z","cvss":[{"version":"3.0","score":9.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-121","CWE-787"],"updated_at":"2026-11-02T14:54:51.069435Z"}],"nvd":[{"id":"CVE-2023-4744","description":"A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.","status":"published","published":"2023-09-04T00:15:07.463Z","modified":"2026-06-17T06:38:30.15Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"secondary"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"},{"version":"2.0","score":10,"vector":"AV:N/AC:L/Au:N/C:C/I:C/A:C","level":"high","assessor":"secondary"}],"cwes":["CWE-121","CWE-787"],"updated_at":"2026-11-02T14:08:27.181588Z"}]}}
