{"id":"CVE-2023-5389","aliases":["EUVD-2023-57704","GHSA-h7wp-7q3v-7m5w"],"status":"published","title":"An attacker could potentially exploit this vulnerability, leading to the ability to modify files...","description":"An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.","severity":{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","level":"critical","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.00779,"percentile":0.56174,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-749"],"published":"2024-01-30T20:00:50Z","modified":"2026-06-17T06:48:29Z","products":[{"vendor":"honeywell","product":"controledge uoc"},{"vendor":"honeywell","product":"controledge_unit_operations_controller_firmware"},{"vendor":"honeywell","product":"controledge_virtual_unit_operations_controller_firmware"}],"references":[{"url":"https://process.honeywell.com","tags":["x_transferred","Product"]},{"url":"https://www.honeywell.com/us/en/product-security","tags":["x_transferred","Not Applicable"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-5389"},{"url":"https://github.com/advisories/GHSA-h7wp-7q3v-7m5w"}],"sources":{"cve":[{"id":"CVE-2023-5389","description":"\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning. ","status":"published","published":"2024-01-30T20:00:50.382Z","modified":"2025-06-17T21:29:17.826Z","cvss":[{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","level":"critical","assessor":"cna"}],"cwes":["CWE-749"],"updated_at":"2026-11-02T14:35:17.149492Z"}],"euvd":[{"id":"EUVD-2023-57704","description":"\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning. ","status":"published","published":"2024-01-30T20:00:50Z","modified":"2025-06-17T21:29:17Z","cvss":[{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","level":"critical"}],"updated_at":"2026-11-02T20:32:20.512078Z"}],"ghsa":[{"id":"GHSA-h7wp-7q3v-7m5w","title":"\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files...","description":"\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion VirtualUOC and UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning. ","status":"published","published":"2024-01-30T21:30:29Z","modified":"2024-01-30T21:30:34Z","cvss":[{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","level":"critical"}],"cwes":["CWE-749"],"updated_at":"2026-11-02T14:55:30.717237Z"}],"nvd":[{"id":"CVE-2023-5389","description":"\nAn attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning. ","status":"published","published":"2024-01-30T20:15:45.42Z","modified":"2026-06-17T06:48:29.577Z","cvss":[{"version":"3.1","score":9.1,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","level":"critical","assessor":"secondary"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","level":"high","assessor":"primary"}],"cwes":["CWE-749"],"updated_at":"2026-11-02T14:09:04.527564Z"}]}}