{"id":"CVE-2023-5405","aliases":["EUVD-2023-57720","GHSA-38mp-fjx9-rc96"],"status":"published","title":"Server information leak for the CDA Server process memory can occur when an error is generated in...","description":"Server information leak for the CDA Server process memory can occur when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.","severity":{"version":"3.1","score":5.9,"vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.00404,"percentile":0.34912,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-787"],"published":"2024-04-17T16:46:29Z","modified":"2026-06-17T06:48:31Z","products":[{"vendor":"honeywell","product":"experion server"},{"vendor":"honeywell","product":"experion_server"}],"references":[{"url":"https://process.honeywell.com","tags":["x_transferred"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2023-5405"},{"url":"https://github.com/advisories/GHSA-38mp-fjx9-rc96"}],"sources":{"cve":[{"id":"CVE-2023-5405","description":"Server information leak for the CDA Server process memory can occur when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.","status":"published","published":"2024-04-17T16:46:29.95Z","modified":"2025-02-06T16:54:27.235Z","cvss":[{"version":"3.1","score":5.9,"vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"cna"},{"version":"3.1","score":5.9,"vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"adp"}],"cwes":["CWE-787","CWE-787"],"updated_at":"2026-11-02T14:35:16.771348Z"}],"euvd":[{"id":"EUVD-2023-57720","description":"Server information leak for the CDA Server process memory can occur when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.","status":"published","published":"2024-04-17T16:46:29Z","modified":"2025-02-06T16:54:27Z","cvss":[{"version":"3.1","score":5.9,"vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium"}],"updated_at":"2026-11-03T00:04:03.312509Z"}],"ghsa":[{"id":"GHSA-38mp-fjx9-rc96","title":"Server information leak for the CDA Server process memory can occur when an error is generated in...","description":"Server information leak for the CDA Server process memory can occur when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.\n\n","status":"published","published":"2024-04-17T18:31:35Z","modified":"2024-04-17T18:31:37Z","cvss":[{"version":"3.1","score":5.9,"vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium"}],"cwes":["CWE-787"],"updated_at":"2026-11-02T14:57:13.502248Z"}],"nvd":[{"id":"CVE-2023-5405","description":"Server information leak for the CDA Server process memory can occur when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.","status":"published","published":"2024-04-17T17:15:14.3Z","modified":"2026-06-17T06:48:31.623Z","cvss":[{"version":"3.1","score":5.9,"vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"secondary"},{"version":"3.1","score":5.9,"vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"secondary"}],"cwes":["CWE-787"],"updated_at":"2026-11-02T14:09:11.362739Z"}]}}