{"id":"CVE-2024-12371","aliases":["EUVD-2024-50811","GHSA-j755-fp8f-xrcg"],"status":"published","title":"Rockwell Automation PowerMonitor™ 1000 Remote Code Execution","description":"A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset.","severity":{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"critical","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-12","score":0.00546,"percentile":0.46285,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-306"],"published":"2024-12-18T15:23:37Z","modified":"2026-06-17T06:59:35Z","products":[{"vendor":"rockwell automation","product":"pm1k 1408-bc3a-485"},{"vendor":"rockwell automation","product":"pm1k 1408-bc3a-ent"},{"vendor":"rockwell automation","product":"pm1k 1408-em1a-485"},{"vendor":"rockwell automation","product":"pm1k 1408-em1a-ent"},{"vendor":"rockwell automation","product":"pm1k 1408-em2a-485"},{"vendor":"rockwell automation","product":"pm1k 1408-em2a-ent"},{"vendor":"rockwell automation","product":"pm1k 1408-em3a-485"},{"vendor":"rockwell automation","product":"pm1k 1408-em3a-ent"},{"vendor":"rockwell automation","product":"pm1k 1408-tr1a-485"},{"vendor":"rockwell automation","product":"pm1k 1408-tr1a-ent"},{"vendor":"rockwell automation","product":"pm1k 1408-tr2a-485"},{"vendor":"rockwell automation","product":"pm1k 1408-tr2a-ent"},{"vendor":"rockwell automation","product":"pm1k 1408-ts3a-485"},{"vendor":"rockwell automation","product":"pm1k 1408-ts3a-ent"}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1714.html"},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2024-12371"},{"url":"https://github.com/advisories/GHSA-j755-fp8f-xrcg"}],"sources":{"cve":[{"id":"CVE-2024-12371","title":"Rockwell Automation PowerMonitor™ 1000 Remote Code Execution","description":"A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset.","status":"published","published":"2024-12-18T15:23:37.736Z","modified":"2024-12-18T19:59:35.81Z","cvss":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"critical","assessor":"cna"}],"cwes":["CWE-306"],"updated_at":"2026-11-02T14:34:11.97482Z"}],"euvd":[{"id":"EUVD-2024-50811","description":"A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset.","status":"published","published":"2024-12-18T15:23:37Z","modified":"2024-12-18T19:59:35Z","cvss":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"critical"}],"updated_at":"2026-11-03T00:04:34.09119Z"}],"ghsa":[{"id":"GHSA-j755-fp8f-xrcg","title":"A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This...","description":"A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset.","status":"published","published":"2024-12-18T18:30:52Z","modified":"2024-12-18T21:30:55Z","cvss":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"critical"}],"cwes":["CWE-306"],"updated_at":"2026-11-02T14:59:14.104556Z"}],"nvd":[{"id":"CVE-2024-12371","description":"A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset.","status":"published","published":"2024-12-18T16:15:10.907Z","modified":"2026-06-17T06:59:35.667Z","cvss":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"critical","assessor":"secondary"}],"cwes":["CWE-306"],"updated_at":"2026-11-02T14:10:40.507978Z"}]}}