{"id":"CVE-2024-22383","aliases":["EUVD-2024-19940","GHSA-53fj-qqg7-vmgv"],"status":"published","title":"Missing release of resource after effective lifetime (CWE-772) in the Controller 7000 resulted...","description":"Missing release of resource after effective lifetime (CWE-772) in the Controller 7000 resulted in HBUS connected T-Series readers to not automatically recover after coming under attack over the RS-485 interface, resulting in a persistent denial of service. \n\nThis issue affects: All variants of the Gallagher Controller 7000 9.00 prior to vCR9.00.231204b (distributed in 9.00.1507(MR1)), 8.90 prior to vCR8.90.240209b (distributed in 8.90.1751 (MR3)), 8.80 prior to vCR8.80.240209a (distributed in 8.80.1526 (MR4)), 8.70 prior to vCR8.70.240209a (distributed in 8.70.2526 (MR6)).","severity":{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"medium","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00173,"percentile":0.06738,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-772"],"published":"2024-03-05T03:12:29Z","modified":"2026-06-17T07:11:17Z","products":[{"vendor":"gallagher","product":"controller 7000"}],"references":[{"url":"https://security.gallagher.com/en-NZ/Security-Advisories/CVE-2024-22383","tags":["x_transferred"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2024-22383"},{"url":"https://github.com/advisories/GHSA-53fj-qqg7-vmgv"}],"sources":{"cve":[{"id":"CVE-2024-22383","description":"\nMissing release of resource after effective lifetime (CWE-772) in the Controller 7000 resulted in HBUS connected T-Series readers to not automatically recover after coming under attack over the RS-485 interface, resulting in a persistent denial of service. \n\nThis issue affects: All variants of the Gallagher Controller 7000 9.00 prior to vCR9.00.231204b (distributed in 9.00.1507(MR1)), 8.90 prior to vCR8.90.240209b (distributed in 8.90.1751 (MR3)), 8.80 prior to vCR8.80.240209a (distributed in 8.80.1526 (MR4)), 8.70 prior to vCR8.70.240209a (distributed in 8.70.2526 (MR6)).\n\n\n\n","status":"published","published":"2024-03-05T03:12:29.581Z","modified":"2024-08-01T22:43:34.539Z","cvss":[{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"medium","assessor":"cna"}],"cwes":["CWE-772"],"updated_at":"2026-11-02T14:33:59.884489Z"}],"euvd":[{"id":"EUVD-2024-19940","description":"\nMissing release of resource after effective lifetime (CWE-772) in the Controller 7000 resulted in HBUS connected T-Series readers to not automatically recover after coming under attack over the RS-485 interface, resulting in a persistent denial of service. \n\nThis issue affects: All variants of the Gallagher Controller 7000 9.00 prior to vCR9.00.231204b (distributed in 9.00.1507(MR1)), 8.90 prior to vCR8.90.240209b (distributed in 8.90.1751 (MR3)), 8.80 prior to vCR8.80.240209a (distributed in 8.80.1526 (MR4)), 8.70 prior to vCR8.70.240209a (distributed in 8.70.2526 (MR6)).\n\n\n\n","status":"published","published":"2024-03-05T03:12:29Z","modified":"2024-08-01T22:43:34Z","cvss":[{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"medium"}],"updated_at":"2026-11-03T03:50:29.401303Z"}],"ghsa":[{"id":"GHSA-53fj-qqg7-vmgv","title":"\nMissing release of resource after effective lifetime (CWE-772) in the Controller 7000 resulted...","description":"\nMissing release of resource after effective lifetime (CWE-772) in the Controller 7000 resulted in HBUS connected T-Series readers to not automatically recover after coming under attack over the RS-485 interface, resulting in a persistent denial of service. \n\nThis issue affects: All variants of the Gallagher Controller 7000 9.00 prior to vCR9.00.231204b (distributed in 9.00.1507(MR1)), 8.90 prior to vCR8.90.240209b (distributed in 8.90.1751 (MR3)), 8.80 prior to vCR8.80.240209a (distributed in 8.80.1526 (MR4)), 8.70 prior to vCR8.70.240209a (distributed in 8.70.2526 (MR6)).\n\n\n\n","status":"published","published":"2024-03-05T03:30:31Z","modified":"2024-03-05T03:30:38Z","cvss":[{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"medium"}],"cwes":["CWE-772"],"updated_at":"2026-11-02T14:55:38.39087Z"}],"nvd":[{"id":"CVE-2024-22383","description":"\nMissing release of resource after effective lifetime (CWE-772) in the Controller 7000 resulted in HBUS connected T-Series readers to not automatically recover after coming under attack over the RS-485 interface, resulting in a persistent denial of service. \n\nThis issue affects: All variants of the Gallagher Controller 7000 9.00 prior to vCR9.00.231204b (distributed in 9.00.1507(MR1)), 8.90 prior to vCR8.90.240209b (distributed in 8.90.1751 (MR3)), 8.80 prior to vCR8.80.240209a (distributed in 8.80.1526 (MR4)), 8.70 prior to vCR8.70.240209a (distributed in 8.70.2526 (MR6)).\n\n\n\n","status":"published","published":"2024-03-05T03:15:06.47Z","modified":"2026-06-17T07:11:17.897Z","cvss":[{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"medium","assessor":"secondary"}],"cwes":["CWE-772"],"updated_at":"2026-11-02T14:09:39.488031Z"}]}}