{"id":"CVE-2024-24330","aliases":["EUVD-2024-21752","GHSA-jm98-mxmf-qcjw"],"status":"published","title":"TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection...","description":"TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the port or enable parameter in the setRemoteCfg function.","severity":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary","from":"nvd"},"epss":{"day":"2026-11-10","score":0.01517,"percentile":0.7476,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-78"],"published":"2024-01-30T00:00:00Z","modified":"2026-06-17T07:14:21Z","products":[{"vendor":"totolink","product":"a3300r_firmware"}],"references":[{"url":"https://github.com/funny-mud-peee/IoT-vuls/blob/main/TOTOLINK%20A3300R/14/TOTOlink%20A3300R%20setRemoteCfg.md","tags":["x_transferred","Exploit","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2024-24330"},{"url":"https://github.com/advisories/GHSA-jm98-mxmf-qcjw"}],"sources":{"cve":[{"id":"CVE-2024-24330","description":"TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the port or enable parameter in the setRemoteCfg function.","status":"published","published":"2024-01-30T00:00:00Z","modified":"2025-06-09T18:34:26.045Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"adp"}],"cwes":["CWE-78"],"updated_at":"2026-11-02T14:34:13.991836Z"}],"euvd":[{"id":"EUVD-2024-21752","description":"TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the port or enable parameter in the setRemoteCfg function.","status":"published","published":"2024-01-30T00:00:00Z","modified":"2025-06-09T18:34:26Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"updated_at":"2026-11-02T20:32:27.346488Z"}],"ghsa":[{"id":"GHSA-jm98-mxmf-qcjw","title":"TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection...","description":"TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the port or enable parameter in the setRemoteCfg function.","status":"published","published":"2024-01-30T15:30:23Z","modified":"2024-02-10T05:07:39Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-78"],"updated_at":"2026-11-02T14:55:35.197353Z"}],"nvd":[{"id":"CVE-2024-24330","description":"TOTOLINK A3300R V17.0.0cu.557_B20221024 was discovered to contain a command injection vulnerability via the port or enable parameter in the setRemoteCfg function.","status":"published","published":"2024-01-30T15:15:09.597Z","modified":"2026-06-17T07:14:21.897Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"secondary"}],"cwes":["CWE-78"],"updated_at":"2026-11-02T14:09:34.891666Z"}]}}
