{"id":"CVE-2024-2899","aliases":["EUVD-2024-27843","GHSA-hqfx-hf4r-r274"],"status":"published","title":"Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow","description":"A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","severity":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.01683,"percentile":0.77135,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-121","CWE-787"],"published":"2024-03-26T19:00:07Z","modified":"2026-06-17T07:25:46Z","products":[{"vendor":"tenda","product":"ac7"},{"vendor":"tenda","product":"ac7_firmware"}],"references":[{"url":"https://vuldb.com/?id.257942","tags":["vdb-entry","technical-description","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://vuldb.com/?ctiid.257942","tags":["signature","permissions-required","x_transferred","Permissions Required","Third Party Advisory","VDB Entry"]},{"url":"https://vuldb.com/?submit.300362","tags":["third-party-advisory","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWirelessRepeat.md","tags":["exploit","x_transferred","Exploit","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2024-2899"},{"url":"https://github.com/advisories/GHSA-hqfx-hf4r-r274"}],"sources":{"cve":[{"id":"CVE-2024-2899","title":"Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow","description":"A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","status":"published","published":"2024-03-26T19:00:07.17Z","modified":"2025-04-10T18:28:47.028Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"},{"version":"3.0","score":8.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","assessor":"cna"}],"cwes":["CWE-121"],"updated_at":"2026-11-02T14:34:09.897248Z"}],"euvd":[{"id":"EUVD-2024-27843","description":"A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","status":"published","published":"2024-03-26T19:00:07Z","modified":"2025-04-10T18:28:47Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-02T20:52:35.819125Z"}],"ghsa":[{"id":"GHSA-hqfx-hf4r-r274","title":"A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44....","description":"A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","status":"published","published":"2024-03-26T21:30:46Z","modified":"2025-01-22T18:31:50Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-121","CWE-787"],"updated_at":"2026-11-02T14:59:37.960322Z"}],"nvd":[{"id":"CVE-2024-2899","description":"A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","status":"published","published":"2024-03-26T19:15:49.41Z","modified":"2026-06-17T07:25:46.957Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","level":"high","assessor":"secondary"}],"cwes":["CWE-121","CWE-787"],"updated_at":"2026-11-02T14:09:43.052376Z"}]}}