{"id":"CVE-2024-32315","aliases":["EUVD-2024-30133","GHSA-p2g5-6h8g-6jr3"],"status":"published","title":"Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the adslPwd parameter...","description":"Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.","severity":{"version":"3.1","score":4.7,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","level":"medium","assessor":"adp","from":"cve"},"epss":{"day":"2026-11-10","score":0.00391,"percentile":0.33537,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-121","CWE-787"],"published":"2024-04-17T00:00:00Z","modified":"2026-06-17T07:29:29Z","products":[{"vendor":"tenda","product":"fh1202"},{"vendor":"tenda","product":"fh1202_firmware"}],"references":[{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/formWanParameterSetting.md","tags":["x_transferred","Broken Link"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2024-32315"},{"url":"https://github.com/advisories/GHSA-p2g5-6h8g-6jr3"}],"sources":{"cve":[{"id":"CVE-2024-32315","description":"Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.","status":"published","published":"2024-04-17T00:00:00Z","modified":"2024-08-02T02:06:44.089Z","cvss":[{"version":"3.1","score":4.7,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","level":"medium","assessor":"adp"}],"cwes":["CWE-121"],"updated_at":"2026-11-02T14:34:15.662528Z"}],"euvd":[{"id":"EUVD-2024-30133","description":"Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.","status":"published","published":"2024-04-17T00:00:00Z","modified":"2024-08-02T02:06:44Z","cvss":[{"version":"3.1","score":4.7,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","level":"medium"}],"updated_at":"2026-11-03T03:50:23.537508Z"}],"ghsa":[{"id":"GHSA-p2g5-6h8g-6jr3","title":"Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the adslPwd parameter...","description":"Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.","status":"published","published":"2024-04-17T15:30:43Z","modified":"2025-04-09T15:32:09Z","cvss":[{"version":"3.1","score":4.7,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","level":"medium"}],"cwes":["CWE-121","CWE-787"],"updated_at":"2026-11-02T15:01:02.112182Z"}],"nvd":[{"id":"CVE-2024-32315","description":"Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.","status":"published","published":"2024-04-17T14:15:09.367Z","modified":"2026-06-17T07:29:29.477Z","cvss":[{"version":"3.1","score":4.7,"vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","level":"medium","assessor":"secondary"}],"cwes":["CWE-787","CWE-121"],"updated_at":"2026-11-02T14:09:52.184911Z"}]}}