{"id":"CVE-2024-3907","aliases":["EUVD-2024-32475","GHSA-qxj9-r243-8955"],"status":"published","title":"Tenda AC500 setcfm formSetCfm stack-based overflow","description":"A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","severity":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.01906,"percentile":0.79897,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-121","CWE-787"],"published":"2024-04-17T11:00:06Z","modified":"2026-06-17T07:45:26Z","products":[{"vendor":"tenda","product":"ac500"},{"vendor":"tenda","product":"ac500_firmware"}],"references":[{"url":"https://vuldb.com/?id.261143","tags":["vdb-entry","technical-description","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://vuldb.com/?ctiid.261143","tags":["signature","permissions-required","x_transferred","Permissions Required","VDB Entry"]},{"url":"https://vuldb.com/?submit.313802","tags":["third-party-advisory","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetCfm.md","tags":["exploit","x_transferred","Exploit","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2024-3907"},{"url":"https://github.com/advisories/GHSA-qxj9-r243-8955"}],"sources":{"cve":[{"id":"CVE-2024-3907","title":"Tenda AC500 setcfm formSetCfm stack-based overflow","description":"A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","status":"published","published":"2024-04-17T11:00:06.424Z","modified":"2024-08-01T20:26:57.13Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"},{"version":"3.0","score":8.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","assessor":"cna"}],"cwes":["CWE-121"],"updated_at":"2026-11-02T14:34:10.613319Z"}],"euvd":[{"id":"EUVD-2024-32475","description":"A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","status":"published","published":"2024-04-17T11:00:06Z","modified":"2024-08-01T20:26:57Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-03T03:50:37.919987Z"}],"ghsa":[{"id":"GHSA-qxj9-r243-8955","title":"A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue...","description":"A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","status":"published","published":"2024-04-17T12:32:05Z","modified":"2025-01-17T21:32:42Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-121","CWE-787"],"updated_at":"2026-11-02T14:59:36.307613Z"}],"nvd":[{"id":"CVE-2024-3907","description":"A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","status":"published","published":"2024-04-17T11:15:12.16Z","modified":"2026-06-17T07:45:26.663Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","level":"high","assessor":"secondary"}],"cwes":["CWE-121","CWE-787"],"updated_at":"2026-11-02T14:09:52.184911Z"}]}}