{"id":"CVE-2024-39582","aliases":["EUVD-2024-38104","GHSA-jh49-frp2-9886"],"status":"published","title":"Dell PowerScale InsightIQ, version 5.0, contain a Use of hard coded Credentials vulnerability. A...","description":"Dell PowerScale InsightIQ, version 5.0, contain a Use of hard coded Credentials vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.","severity":{"version":"3.1","score":2.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N","level":"low","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-10","score":0.00146,"percentile":0.03839,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-798"],"published":"2024-09-10T09:04:50Z","modified":"2026-06-17T07:42:16Z","products":[{"vendor":"dell","product":"insightiq"},{"vendor":"dell","product":"powerscale insightiq"}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000228412/dsa-2024-360-security-update-for-dell-powerscale-insightiq-for-multiple-security-vulnerabilities","tags":["vendor-advisory","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2024-39582"},{"url":"https://github.com/advisories/GHSA-jh49-frp2-9886"}],"sources":{"cve":[{"id":"CVE-2024-39582","description":"Dell PowerScale InsightIQ, version 5.0, contain a Use of hard coded Credentials vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.","status":"published","published":"2024-09-10T09:04:50.035Z","modified":"2024-09-10T13:12:02.943Z","cvss":[{"version":"3.1","score":2.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N","level":"low","assessor":"cna"}],"cwes":["CWE-798"],"updated_at":"2026-11-02T14:34:19.28149Z"}],"euvd":[{"id":"EUVD-2024-38104","description":"Dell PowerScale InsightIQ, version 5.0, contain a Use of hard coded Credentials vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.","status":"published","published":"2024-09-10T09:04:50Z","modified":"2024-09-10T13:12:02Z","cvss":[{"version":"3.1","score":2.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N","level":"low"}],"updated_at":"2026-11-03T00:56:00.258951Z"}],"ghsa":[{"id":"GHSA-jh49-frp2-9886","title":"Dell PowerScale InsightIQ, version 5.0, contain a Use of hard coded Credentials vulnerability. A...","description":"Dell PowerScale InsightIQ, version 5.0, contain a Use of hard coded Credentials vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.","status":"published","published":"2024-09-10T09:31:11Z","modified":"2024-09-10T09:31:18Z","cvss":[{"version":"3.1","score":2.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N","level":"low"}],"cwes":["CWE-798"],"updated_at":"2026-11-02T14:58:13.090684Z"}],"nvd":[{"id":"CVE-2024-39582","description":"Dell PowerScale InsightIQ, version 5.0, contain a Use of hard coded Credentials vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure.","status":"published","published":"2024-09-10T09:15:03.243Z","modified":"2026-06-17T07:42:16.637Z","cvss":[{"version":"3.1","score":2.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N","level":"low","assessor":"secondary"},{"version":"3.1","score":4.4,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"primary"}],"cwes":["CWE-798"],"updated_at":"2026-11-02T14:10:25.561537Z"}]}}