{"id":"CVE-2024-41798","aliases":["EUVD-2024-39189","GHSA-rcxw-v8q3-f2f8"],"status":"published","title":"A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only...","description":"A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by sniffing the Modbus clear text communication.","severity":{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"critical","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00542,"percentile":0.46011,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-287"],"published":"2024-10-08T08:40:16Z","modified":"2026-06-17T07:48:15Z","products":[{"vendor":"siemens","product":"sentron 7km pac3200"},{"vendor":"siemens","product":"sentron_pac3200"}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-850560.html"},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2024-41798"},{"url":"https://github.com/advisories/GHSA-rcxw-v8q3-f2f8"}],"sources":{"cve":[{"id":"CVE-2024-41798","description":"A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by sniffing the Modbus clear text communication.","status":"published","published":"2024-10-08T08:40:16.947Z","modified":"2024-10-08T14:06:17.123Z","cvss":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"critical","assessor":"cna"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"cna"}],"cwes":["CWE-287"],"updated_at":"2026-11-02T14:34:03.661584Z"}],"euvd":[{"id":"EUVD-2024-39189","description":"A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by sniffing the Modbus clear text communication.","status":"published","published":"2024-10-08T08:40:16Z","modified":"2024-10-08T14:06:17Z","cvss":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"critical"}],"updated_at":"2026-11-03T00:27:45.808193Z"}],"ghsa":[{"id":"GHSA-rcxw-v8q3-f2f8","title":"A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only...","description":"A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by sniffing the Modbus clear text communication.","status":"published","published":"2024-10-08T09:30:53Z","modified":"2024-10-08T09:30:53Z","cvss":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"critical"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-287"],"updated_at":"2026-11-02T14:58:26.306971Z"}],"nvd":[{"id":"CVE-2024-41798","description":"A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by sniffing the Modbus clear text communication.","status":"published","published":"2024-10-08T09:15:11.177Z","modified":"2026-06-17T07:48:15.253Z","cvss":[{"version":"4.0","score":9.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"critical","assessor":"secondary"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"secondary"}],"cwes":["CWE-287"],"updated_at":"2026-11-02T14:10:31.271525Z"}]}}
