{"id":"CVE-2024-4491","aliases":["EUVD-2024-44105","GHSA-pmf3-wffg-82x2"],"status":"published","title":"Tenda i21 formGetDiagnoseInfo stack-based overflow","description":"A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","severity":{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.01453,"percentile":0.73766,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-121","CWE-787"],"published":"2024-05-04T23:31:04Z","modified":"2026-06-17T08:01:58Z","products":[{"vendor":"tenda","product":"i21"},{"vendor":"tenda","product":"i21_firmware"}],"references":[{"url":"https://vuldb.com/?id.263080","tags":["vdb-entry","technical-description","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://vuldb.com/?ctiid.263080","tags":["signature","permissions-required","x_transferred","Permissions Required","Third Party Advisory","VDB Entry"]},{"url":"https://vuldb.com/?submit.323600","tags":["third-party-advisory","x_transferred","Third Party Advisory","VDB Entry"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formGetDiagnoseInfo.md","tags":["exploit","x_transferred","Broken Link"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2024-4491"},{"url":"https://github.com/advisories/GHSA-pmf3-wffg-82x2"}],"sources":{"cve":[{"id":"CVE-2024-4491","title":"Tenda i21 formGetDiagnoseInfo stack-based overflow","description":"A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","status":"published","published":"2024-05-04T23:31:04.379Z","modified":"2024-08-01T20:40:47.383Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"},{"version":"3.0","score":8.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","assessor":"cna"}],"cwes":["CWE-121"],"updated_at":"2026-11-02T14:34:17.150655Z"}],"euvd":[{"id":"EUVD-2024-44105","description":"A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","status":"published","published":"2024-05-04T23:31:04Z","modified":"2024-08-01T20:40:47Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-03T03:50:36.775345Z"}],"ghsa":[{"id":"GHSA-pmf3-wffg-82x2","title":"A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability...","description":"A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","status":"published","published":"2024-05-05T00:30:31Z","modified":"2025-01-27T21:30:48Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-121","CWE-787"],"updated_at":"2026-11-02T14:59:41.697715Z"}],"nvd":[{"id":"CVE-2024-4491","description":"A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","status":"published","published":"2024-05-05T00:15:07.373Z","modified":"2026-06-17T08:01:58.99Z","cvss":[{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","level":"high","assessor":"secondary"}],"cwes":["CWE-121","CWE-787"],"updated_at":"2026-11-02T14:09:56.122111Z"}]}}
