{"id":"CVE-2024-6918","aliases":["EUVD-2024-47905","GHSA-78pr-7p6m-3mmv"],"status":"published","title":"CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability...","description":"CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability\nexists that could cause a crash of the Accutech Manager when receiving a specially crafted\nrequest over port 2536/TCP.","severity":{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-08","score":0.00484,"percentile":0.4198,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-120"],"published":"2024-08-20T12:11:23Z","modified":"2026-06-17T08:18:58Z","products":[{"vendor":"schneider electric","product":"accutech manager"},{"vendor":"schneider-electric","product":"accutech_manager"}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-226-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-226-01.pdf"},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2024-6918"},{"url":"https://github.com/advisories/GHSA-78pr-7p6m-3mmv"}],"sources":{"cve":[{"id":"CVE-2024-6918","description":"CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability\nexists that could cause a crash of the Accutech Manager when receiving a specially crafted\nrequest over port 2536/TCP.","status":"published","published":"2024-08-20T12:11:23.899Z","modified":"2024-09-03T17:08:31.244Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"high","assessor":"cna"}],"cwes":["CWE-120"],"updated_at":"2026-11-02T14:34:11.305983Z"}],"euvd":[{"id":"EUVD-2024-47905","description":"CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability\nexists that could cause a crash of the Accutech Manager when receiving a specially crafted\nrequest over port 2536/TCP.","status":"published","published":"2024-08-20T12:11:23Z","modified":"2024-09-03T17:08:31Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"high"}],"updated_at":"2026-11-03T00:56:05.515988Z"}],"ghsa":[{"id":"GHSA-78pr-7p6m-3mmv","title":"CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability...","description":"CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability\nexists that could cause a crash of the Accutech Manager when receiving a specially crafted\nrequest over port 2536/TCP.","status":"published","published":"2024-08-20T15:32:13Z","modified":"2024-08-20T15:32:25Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"high"}],"cwes":["CWE-120"],"updated_at":"2026-11-02T14:58:01.327673Z"}],"nvd":[{"id":"CVE-2024-6918","description":"CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability\nexists that could cause a crash of the Accutech Manager when receiving a specially crafted\nrequest over port 2536/TCP.","status":"published","published":"2024-08-20T13:15:09.45Z","modified":"2026-06-17T08:18:58.607Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","level":"high","assessor":"secondary"}],"cwes":["CWE-120"],"updated_at":"2026-11-02T14:10:19.870727Z"}]}}