{"id":"CVE-2025-10814","aliases":["EUVD-2025-30455","GHSA-w85c-w3c2-gf9p"],"status":"published","title":"D-Link DIR-823X goahead command injection","description":"A vulnerability was determined in D-Link DIR-823X 240126/240802/250416. Affected by this vulnerability is an unknown functionality of the file /usr/sbin/goahead. This manipulation of the argument port causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized.","severity":{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P","level":"medium","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.05246,"percentile":0.92639,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-74","CWE-77"],"published":"2025-09-22T20:32:09Z","modified":"2026-10-11T20:10:00Z","products":[{"vendor":"d-link","product":"dir-823x"},{"vendor":"dlink","product":"dir-823x_firmware"}],"references":[{"url":"https://vuldb.com/?id.325172","tags":["vdb-entry","technical-description","Third Party Advisory","VDB Entry"]},{"url":"https://vuldb.com/?ctiid.325172","tags":["signature","permissions-required","Permissions Required","VDB Entry"]},{"url":"https://vuldb.com/?submit.654452","tags":["third-party-advisory","Third Party Advisory","VDB Entry"]},{"url":"https://github.com/W1ngyu/cve/blob/main/DIink-DIR-823xgoformset_server_settings_command_execution_vulnerability.md","tags":["exploit","Exploit","Third Party Advisory"]},{"url":"https://www.dlink.com/","tags":["product","Product"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-10814"},{"url":"https://www.dlink.com"},{"url":"https://github.com/advisories/GHSA-w85c-w3c2-gf9p"}],"sources":{"cve":[{"id":"CVE-2025-10814","title":"D-Link DIR-823X goahead command injection","description":"A vulnerability was determined in D-Link DIR-823X 240126/240802/250416. Affected by this vulnerability is an unknown functionality of the file /usr/sbin/goahead. This manipulation of the argument port causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized.","status":"published","published":"2025-09-22T20:32:09.997Z","modified":"2025-09-23T20:17:43.98Z","cvss":[{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P","level":"medium","assessor":"cna"},{"version":"3.1","score":6.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R","level":"medium","assessor":"cna"},{"version":"3.0","score":6.3,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R","level":"medium","assessor":"cna"},{"version":"2.0","score":6.5,"vector":"AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR","assessor":"cna"}],"cwes":["CWE-77","CWE-74"],"updated_at":"2026-11-02T14:32:30.9782Z"}],"euvd":[{"id":"EUVD-2025-30455","description":"A vulnerability was determined in D-Link DIR-823X 240126/240802/250416. Affected by this vulnerability is an unknown functionality of the file /usr/sbin/goahead. This manipulation of the argument port causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized.","status":"published","published":"2025-09-22T20:32:09Z","modified":"2025-09-23T20:17:43Z","cvss":[{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P","level":"medium"}],"updated_at":"2026-11-02T20:31:40.470019Z"}],"ghsa":[{"id":"GHSA-w85c-w3c2-gf9p","title":"A vulnerability was determined in D-Link DIR-823X 240126/240802/250416. Affected by this...","description":"A vulnerability was determined in D-Link DIR-823X 240126/240802/250416. Affected by this vulnerability is an unknown functionality of the file /usr/sbin/goahead. This manipulation of the argument port causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized.","status":"published","published":"2025-09-22T21:30:29Z","modified":"2025-09-22T21:30:37Z","cvss":[{"version":"4.0","score":2.1,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"low"},{"version":"3.1","score":6.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","level":"medium"}],"cwes":["CWE-74"],"updated_at":"2026-11-02T15:03:43.092061Z"}],"nvd":[{"id":"CVE-2025-10814","description":"A vulnerability was determined in D-Link DIR-823X 240126/240802/250416. Affected by this vulnerability is an unknown functionality of the file /usr/sbin/goahead. This manipulation of the argument port causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized.","status":"published","published":"2025-09-22T21:15:58.733Z","modified":"2026-10-11T20:10:00.2Z","cvss":[{"version":"4.0","score":2.1,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"low","assessor":"secondary"},{"version":"3.1","score":6.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","level":"medium","assessor":"secondary"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"},{"version":"2.0","score":6.5,"vector":"AV:N/AC:L/Au:S/C:P/I:P/A:P","level":"medium","assessor":"secondary"}],"cwes":["CWE-74","CWE-77"],"updated_at":"2026-11-02T14:11:32.559087Z"}]}}