{"id":"CVE-2025-11387","aliases":["EUVD-2025-32101","GHSA-g45x-wv5j-2hj5"],"status":"published","title":"Tenda AC15 fast_setting_pppoe_set stack-based overflow","description":"A vulnerability was determined in Tenda AC15 15.03.05.18. This affects an unknown function of the file /goform/fast_setting_pppoe_set. This manipulation of the argument Password causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.","severity":{"version":"4.0","score":8.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-10","score":0.00817,"percentile":0.57448,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-119","CWE-121"],"published":"2025-10-07T10:32:07Z","modified":"2026-10-08T22:10:00Z","products":[{"vendor":"tenda","product":"ac15"},{"vendor":"tenda","product":"ac15_firmware"}],"references":[{"url":"https://vuldb.com/?id.327314","tags":["vdb-entry","technical-description","Third Party Advisory","VDB Entry"]},{"url":"https://vuldb.com/?ctiid.327314","tags":["signature","permissions-required","Permissions Required","VDB Entry"]},{"url":"https://vuldb.com/?submit.664970","tags":["third-party-advisory","Third Party Advisory","VDB Entry"]},{"url":"https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC15/fast_setting_pppoe_set.md","tags":["exploit","Exploit","Third Party Advisory"]},{"url":"https://www.tenda.com.cn/","tags":["product","Product"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-11387"},{"url":"https://www.tenda.com.cn"},{"url":"https://github.com/advisories/GHSA-g45x-wv5j-2hj5"}],"sources":{"cve":[{"id":"CVE-2025-11387","title":"Tenda AC15 fast_setting_pppoe_set stack-based overflow","description":"A vulnerability was determined in Tenda AC15 15.03.05.18. This affects an unknown function of the file /goform/fast_setting_pppoe_set. This manipulation of the argument Password causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.","status":"published","published":"2025-10-07T10:32:07.045Z","modified":"2026-02-24T06:48:00.599Z","cvss":[{"version":"4.0","score":8.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","level":"high","assessor":"cna"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R","level":"high","assessor":"cna"},{"version":"3.0","score":8.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R","level":"high","assessor":"cna"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR","assessor":"cna"}],"cwes":["CWE-121","CWE-119"],"updated_at":"2026-11-02T14:32:51.199669Z"}],"euvd":[{"id":"EUVD-2025-32101","description":"A vulnerability was determined in Tenda AC15 15.03.05.18. This affects an unknown function of the file /goform/fast_setting_pppoe_set. This manipulation of the argument Password causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.","status":"published","published":"2025-10-07T10:32:07Z","modified":"2026-02-24T06:48:00Z","cvss":[{"version":"4.0","score":8.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","level":"high"}],"updated_at":"2026-11-02T19:48:30.447815Z"}],"ghsa":[{"id":"GHSA-g45x-wv5j-2hj5","title":"A vulnerability was determined in Tenda AC15 15.03.05.18. This affects an unknown function of the...","description":"A vulnerability was determined in Tenda AC15 15.03.05.18. This affects an unknown function of the file /goform/fast_setting_pppoe_set. This manipulation of the argument Password causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.","status":"published","published":"2025-10-07T12:31:16Z","modified":"2025-10-07T12:31:21Z","cvss":[{"version":"4.0","score":7.4,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-119"],"updated_at":"2026-11-02T15:03:52.40546Z"}],"nvd":[{"id":"CVE-2025-11387","description":"A vulnerability was determined in Tenda AC15 15.03.05.18. This affects an unknown function of the file /goform/fast_setting_pppoe_set. This manipulation of the argument Password causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.","status":"published","published":"2025-10-07T11:16:01.5Z","modified":"2026-10-08T22:10:00.563Z","cvss":[{"version":"4.0","score":7.4,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high","assessor":"secondary"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","level":"high","assessor":"secondary"}],"cwes":["CWE-119","CWE-121"],"updated_at":"2026-11-02T14:11:35.93863Z"}]}}
