{"id":"CVE-2025-11567","aliases":["EUVD-2025-131908","GHSA-vr2h-fpfm-62g7"],"status":"published","title":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system...","description":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.","severity":{"version":"4.0","score":7.3,"vector":"CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00131,"percentile":0.02753,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-276"],"published":"2025-11-12T13:27:56Z","modified":"2026-10-18T20:10:00Z","products":[{"vendor":"schneider electric","product":"powerchute™ serial shutdown"}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-315-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-315-01.pdf"},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-11567"},{"url":"https://github.com/advisories/GHSA-vr2h-fpfm-62g7"}],"sources":{"cve":[{"id":"CVE-2025-11567","description":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.","status":"published","published":"2025-11-12T13:27:56.004Z","modified":"2025-11-12T18:50:03.699Z","cvss":[{"version":"4.0","score":7.3,"vector":"CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"high","assessor":"cna"}],"cwes":["CWE-276"],"updated_at":"2026-11-02T14:32:50.872559Z"}],"euvd":[{"id":"EUVD-2025-131908","description":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.","status":"published","published":"2025-11-12T13:27:56Z","modified":"2025-11-12T18:50:03Z","cvss":[{"version":"4.0","score":7.3,"vector":"CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"high"}],"updated_at":"2026-11-02T19:49:18.397537Z"}],"ghsa":[{"id":"GHSA-vr2h-fpfm-62g7","title":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system...","description":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.","status":"published","published":"2025-11-12T15:31:29Z","modified":"2025-11-12T15:31:30Z","cvss":[{"version":"4.0","score":7.3,"vector":"CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high"}],"cwes":["CWE-276"],"updated_at":"2026-11-02T15:04:45.782037Z"}],"nvd":[{"id":"CVE-2025-11567","description":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.","status":"published","published":"2025-11-12T14:15:46.733Z","modified":"2026-10-18T20:10:00.11Z","cvss":[{"version":"4.0","score":7.3,"vector":"CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high","assessor":"secondary"}],"cwes":["CWE-276"],"updated_at":"2026-11-02T14:11:43.650381Z"}]}}