{"id":"CVE-2025-14096","aliases":["EUVD-2025-203889","GHSA-h5qw-42jq-7cmh"],"status":"published","title":"Credential Disclosure vulnerability in Radiometer Products","description":"A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.\n\nOther related CVE's are CVE-2025-14095 \u0026 CVE-2025-14097.\n\n\n\nAffected customers have been informed about this vulnerability. This CVE is being published to provide transparency.\n\n\n\n\n\nRequired Configuration for Exposure:\n\n\nAttacker requires physical access to the analyzer.\n\n\n\nTemporary work Around:\nOnly authorized people can physically access the analyzer.\n\nPermanent solution:\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution.\n\nExploit Status:\n\n\nResearchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication.","severity":{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-12","score":0.00135,"percentile":0.03019,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-250","CWE-798"],"published":"2025-12-17T12:19:27Z","modified":"2026-06-17T08:35:19Z","products":[{"vendor":"radiometer medical aps","product":"abl800 basic and abl800 flex analyzers"},{"vendor":"radiometer medical aps","product":"abl90 flex and abl90 flex plus analyzers"},{"vendor":"radiometer medical aps","product":"aqt90 flex analyzers"}],"references":[{"url":"https://www.radiometer.com/myradiometer"},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-14096"},{"url":"https://github.com/advisories/GHSA-h5qw-42jq-7cmh"}],"sources":{"cve":[{"id":"CVE-2025-14096","title":"Credential Disclosure vulnerability in Radiometer Products","description":"A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.\n\nOther related CVE's are CVE-2025-14095 \u0026 CVE-2025-14097.\n\n\n\nAffected customers have been informed about this vulnerability. This CVE is being published to provide transparency.\n\n\n\n\n\nRequired Configuration for Exposure:\n\n\nAttacker requires physical access to the analyzer.\n\n\n\nTemporary work Around:\nOnly authorized people can physically access the analyzer.\n\nPermanent solution:\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution.\n\nExploit Status:\n\n\nResearchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication.","status":"published","published":"2025-12-17T12:19:27.489Z","modified":"2025-12-17T14:43:16.523Z","cvss":[{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"}],"cwes":["CWE-798","CWE-250"],"updated_at":"2026-11-02T14:32:28.621398Z"}],"euvd":[{"id":"EUVD-2025-203889","description":"A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.\n\nOther related CVE's are CVE-2025-14095 \u0026 CVE-2025-14097.\n\n\n\nAffected customers have been informed about this vulnerability. This CVE is being published to provide transparency.\n\n\n\n\n\nRequired Configuration for Exposure:\n\n\nAttacker requires physical access to the analyzer.\n\n\n\nTemporary work Around:\nOnly authorized people can physically access the analyzer.\n\nPermanent solution:\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution.\n\nExploit Status:\n\n\nResearchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication.","status":"published","published":"2025-12-17T12:19:27Z","modified":"2025-12-17T14:43:16Z","cvss":[{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-02T19:49:04.015486Z"}],"ghsa":[{"id":"GHSA-h5qw-42jq-7cmh","title":"A vulnerability exists in multiple Radiometer products that allow an attacker with physical...","description":"A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.\n\nOther related CVE's are CVE-2025-14095 \u0026 CVE-2025-14097.\n\n\n\nAffected customers have been informed about this vulnerability. This CVE is being published to provide transparency.\n\n\n\n\n\nRequired Configuration for Exposure:\n\n\nAttacker requires physical access to the analyzer.\n\n\n\nTemporary work Around:\nOnly authorized people can physically access the analyzer.\n\nPermanent solution:\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution.\n\nExploit Status:\n\n\nResearchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication.","status":"published","published":"2025-12-17T15:34:53Z","modified":"2025-12-17T15:35:00Z","cvss":[{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-250"],"updated_at":"2026-11-02T15:05:14.584234Z"}],"nvd":[{"id":"CVE-2025-14096","description":"A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.\n\nOther related CVE's are CVE-2025-14095 \u0026 CVE-2025-14097.\n\n\n\nAffected customers have been informed about this vulnerability. This CVE is being published to provide transparency.\n\n\n\n\n\nRequired Configuration for Exposure:\n\n\nAttacker requires physical access to the analyzer.\n\n\n\nTemporary work Around:\nOnly authorized people can physically access the analyzer.\n\nPermanent solution:\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution.\n\nExploit Status:\n\n\nResearchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication.","status":"published","published":"2025-12-17T13:15:57.89Z","modified":"2026-06-17T08:35:19.237Z","cvss":[{"version":"3.1","score":8.4,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"}],"cwes":["CWE-250","CWE-798"],"updated_at":"2026-11-02T14:11:51.309584Z"}]}}