{"id":"CVE-2025-15627","aliases":["EUVD-2025-210609","GHSA-wwx9-ww39-c5vg"],"status":"published","title":"Hardcoded Cryptographic Keys in TP-Link Omada Adoption Protocol Authentication","description":"A cryptographic\nweakness exists in the Omada adoption protocol. \nThe protocol relies on hard-coded cryptographic keys to establish trust and\nprotect authentication exchanges between controllers and managed devices during\ndevice adoption.\n\n\n\n\n\n\n\n\n\nAn attacker may\nbe able to impersonate trusted controllers or managed devices and gain access\nto sensitive adoption-related communications.","severity":{"version":"4.0","score":6.9,"vector":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:P/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N","level":"medium","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00676,"percentile":0.52665,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-321"],"published":"2026-08-03T17:49:46Z","modified":"2026-09-29T14:10:00Z","products":[{"vendor":"tp link systems inc.","product":"omada access points"},{"vendor":"tp-link","product":"omada_ds1008x_firmware"},{"vendor":"tp-link","product":"omada_ds1016g_firmware"},{"vendor":"tp-link","product":"omada_ds1016ge_firmware"},{"vendor":"tp-link","product":"omada_ds1018gmp_firmware"},{"vendor":"tp-link","product":"omada_ds1024g_firmware"},{"vendor":"tp-link","product":"omada_ds105g-m2_firmware"},{"vendor":"tp-link","product":"omada_ds105g_firmware"},{"vendor":"tp-link","product":"omada_ds105ge_firmware"},{"vendor":"tp-link","product":"omada_ds105gp_firmware"},{"vendor":"tp-link","product":"omada_ds105x_firmware"},{"vendor":"tp-link","product":"omada_ds106gpp_firmware"},{"vendor":"tp-link","product":"omada_ds106p_firmware"},{"vendor":"tp-link","product":"omada_ds108g-m2_firmware"},{"vendor":"tp-link","product":"omada_ds108g_firmware"},{"vendor":"tp-link","product":"omada_ds108ge_firmware"},{"vendor":"tp-link","product":"omada_ds108gp_firmware"},{"vendor":"tp-link","product":"omada_ds110gmp_firmware"},{"vendor":"tp-link","product":"omada_ds111p_firmware"},{"vendor":"tp-link","product":"omada_eap610-outdoor_firmware"},{"vendor":"tp-link","product":"omada_eap610_firmware"},{"vendor":"tp-link","product":"omada_eap615-wall_firmware"},{"vendor":"tp-link","product":"omada_eap620hd_firmware"},{"vendor":"tp-link","product":"omada_eap660hd_firmware"},{"vendor":"tp-link","product":"omada_er605_firmware"},{"vendor":"tp-link","product":"omada_er703wp-4g-outdoor_firmware"},{"vendor":"tp-link","product":"omada_er706w-4g_firmware"},{"vendor":"tp-link","product":"omada_er706w_firmware"},{"vendor":"tp-link","product":"omada_er706wp-4g_firmware"},{"vendor":"tp-link","product":"omada_er707-m2_firmware"},{"vendor":"tp-link","product":"omada_er7206_firmware"},{"vendor":"tp-link","product":"omada_er7412-m2_firmware"},{"vendor":"tp-link","product":"omada_er8411_firmware"},{"vendor":"tp-link","product":"omada_es1024ge_firmware"},{"vendor":"tp-link","product":"omada_es205g_firmware"},{"vendor":"tp-link","product":"omada_es205gp_firmware"},{"vendor":"tp-link","product":"omada_es206gp_firmware"},{"vendor":"tp-link","product":"omada_es206x-m2_firmware"},{"vendor":"tp-link","product":"omada_es206xpp-m2_firmware"},{"vendor":"tp-link","product":"omada_es208g_firmware"},{"vendor":"tp-link","product":"omada_es208gp_firmware"},{"vendor":"tp-link","product":"omada_es210gmp_firmware"},{"vendor":"tp-link","product":"omada_es210gp_firmware"},{"vendor":"tp-link","product":"omada_es210x-m2_firmware"},{"vendor":"tp-link","product":"omada_es210xpp-m2_firmware"},{"vendor":"tp-link","product":"omada_es216g_firmware"},{"vendor":"tp-link","product":"omada_es220gmp_firmware"},{"vendor":"tp-link","product":"omada_es220gp_firmware"},{"vendor":"tp-link","product":"omada_es224g_firmware"},{"vendor":"tp-link","product":"omada_es228gmp_firmware"},{"vendor":"tp-link","product":"omada_es228gp_firmware"},{"vendor":"tp-link","product":"omada_fusion_2.5g_firmware"},{"vendor":"tp-link","product":"omada_ies206g_firmware"},{"vendor":"tp-link","product":"omada_ies206gpp_firmware"},{"vendor":"tp-link","product":"omada_ies208g_firmware"},{"vendor":"tp-link","product":"omada_ies210gpp_firmware"},{"vendor":"tp-link","product":"omada_oc200_v3_firmware"},{"vendor":"tp-link","product":"omada_oc300_firmware"},{"vendor":"tp-link","product":"omada_oc400_firmware"},{"vendor":"tp-link","product":"omada_s6500-24g4xf_firmware"},{"vendor":"tp-link","product":"omada_s6500-24gp4xf_firmware"},{"vendor":"tp-link","product":"omada_s6500-24mpp4y_firmware"},{"vendor":"tp-link","product":"omada_s6500-48g6xf_firmware"},{"vendor":"tp-link","product":"omada_s6500-48gp6xf_firmware"},{"vendor":"tp-link","product":"omada_s6500-48mpp6y_firmware"},{"vendor":"tp-link","product":"omada_s7500-24y4c_firmware"},{"vendor":"tp-link","product":"omada_s7500-26xf6y_firmware"},{"vendor":"tp-link","product":"omada_sg2005p-pd_firmware"},{"vendor":"tp-link","product":"omada_sg2008_firmware"},{"vendor":"tp-link","product":"omada_sg2008p_firmware"},{"vendor":"tp-link","product":"omada_sg2016p_firmware"},{"vendor":"tp-link","product":"omada_sg2206mp_firmware"},{"vendor":"tp-link","product":"omada_sg2210mp_firmware"},{"vendor":"tp-link","product":"omada_sg2210p_firmware"},{"vendor":"tp-link","product":"omada_sg2210xmp-m2_firmware"},{"vendor":"tp-link","product":"omada_sg2218_firmware"},{"vendor":"tp-link","product":"omada_sg2218p_firmware"},{"vendor":"tp-link","product":"omada_sg2428lp_firmware"},{"vendor":"tp-link","product":"omada_sg2428p_firmware"},{"vendor":"tp-link","product":"omada_sg2452lp_firmware"},{"vendor":"tp-link","product":"omada_sg3210_firmware"},{"vendor":"tp-link","product":"omada_sg3210x-m2_firmware"},{"vendor":"tp-link","product":"omada_sg3210xhp-m2_firmware"},{"vendor":"tp-link","product":"omada_sg3218xp-m2_firmware"},{"vendor":"tp-link","product":"omada_sg3428_firmware"},{"vendor":"tp-link","product":"omada_sg3428mp_firmware"},{"vendor":"tp-link","product":"omada_sg3428x-m2_firmware"},{"vendor":"tp-link","product":"omada_sg3428x_firmware"},{"vendor":"tp-link","product":"omada_sg3428xf_firmware"},{"vendor":"tp-link","product":"omada_sg3428xmp_firmware"},{"vendor":"tp-link","product":"omada_sg3428xmpp_firmware"},{"vendor":"tp-link","product":"omada_sg3428xpp-m2_firmware"},{"vendor":"tp-link","product":"omada_sg3452_firmware"},{"vendor":"tp-link","product":"omada_sg3452p_firmware"},{"vendor":"tp-link","product":"omada_sg3452xmpp_firmware"},{"vendor":"tp-link","product":"omada_sg3452xp_firmware"},{"vendor":"tp-link","product":"omada_sg5428x_firmware"},{"vendor":"tp-link","product":"omada_sg5428xmpp_firmware"},{"vendor":"tp-link","product":"omada_sg5452x_firmware"},{"vendor":"tp-link","product":"omada_sg5452xmpp_firmware"},{"vendor":"tp-link","product":"omada_sg6428x_firmware"},{"vendor":"tp-link","product":"omada_sg6428xhp_firmware"},{"vendor":"tp-link","product":"omada_sg6654x_firmware"},{"vendor":"tp-link","product":"omada_sg6654xhp_firmware"},{"vendor":"tp-link","product":"omada_sx3008f_firmware"},{"vendor":"tp-link","product":"omada_sx3016f_firmware"},{"vendor":"tp-link","product":"omada_sx3032f_firmware"},{"vendor":"tp-link","product":"omada_sx3206hpp_firmware"},{"vendor":"tp-link","product":"omada_sx3832_firmware"},{"vendor":"tp-link","product":"omada_sx3832mpp_firmware"},{"vendor":"tp-link","product":"omada_sx6632yf_firmware"},{"vendor":"tp-link","product":"omada_tl-sg3210_firmware"},{"vendor":"tp-link","product":"omada_tl-sg3452x_firmware"},{"vendor":"tp-link systems inc","product":"omada controllers"},{"vendor":"tp-link systems inc.","product":"omada access points"},{"vendor":"tp-link systems inc.","product":"omada gateways"},{"vendor":"tp-link systems inc.","product":"omada switches"}],"references":[{"url":"https://www.omadanetworks.com/us/support/download/","tags":["patch","Product"]},{"url":"https://www.omadanetworks.com/en/support/download/","tags":["patch","Product"]},{"url":"https://www.tp-link.com/us/support/faq/5216/","tags":["vendor-advisory","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-15627"},{"url":"https://www.omadanetworks.com/en/support/download"},{"url":"https://www.omadanetworks.com/us/support/download"},{"url":"https://www.tp-link.com/us/support/faq/5216"},{"url":"https://github.com/advisories/GHSA-wwx9-ww39-c5vg"}],"sources":{"cve":[{"id":"CVE-2025-15627","title":"Hardcoded Cryptographic Keys in TP-Link Omada Adoption Protocol Authentication","description":"A cryptographic\nweakness exists in the Omada adoption protocol. \nThe protocol relies on hard-coded cryptographic keys to establish trust and\nprotect authentication exchanges between controllers and managed devices during\ndevice adoption.\n\n\n\n\n\n\n\n\n\nAn attacker may\nbe able to impersonate trusted controllers or managed devices and gain access\nto sensitive adoption-related communications.","status":"published","published":"2026-08-03T17:49:46.749Z","modified":"2026-08-03T18:33:55.632Z","cvss":[{"version":"4.0","score":6.9,"vector":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:P/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N","level":"medium","assessor":"cna"}],"cwes":["CWE-321"],"updated_at":"2026-11-02T14:32:37.351404Z"}],"euvd":[{"id":"EUVD-2025-210609","description":"A cryptographic\nweakness exists in the Omada adoption protocol. \nThe protocol relies on hard-coded cryptographic keys to establish trust and\nprotect authentication exchanges between controllers and managed devices during\ndevice adoption.\n\n\n\n\n\n\n\n\n\nAn attacker may\nbe able to impersonate trusted controllers or managed devices and gain access\nto sensitive adoption-related communications.","status":"published","published":"2026-08-03T17:49:46Z","modified":"2026-08-03T18:33:55Z","cvss":[{"version":"4.0","score":6.9,"vector":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:P/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N","level":"medium"}],"updated_at":"2026-11-02T18:02:24.01774Z"}],"ghsa":[{"id":"GHSA-wwx9-ww39-c5vg","title":"A cryptographic\nweakness exists in the Omada adoption protocol. \nThe protocol relies on hard...","description":"A cryptographic\nweakness exists in the Omada adoption protocol. \nThe protocol relies on hard-coded cryptographic keys to establish trust and\nprotect authentication exchanges between controllers and managed devices during\ndevice adoption.\n\n\n\n\n\n\n\n\n\nAn attacker may\nbe able to impersonate trusted controllers or managed devices and gain access\nto sensitive adoption-related communications.","status":"published","published":"2026-08-03T21:31:35Z","modified":"2026-08-07T15:34:06Z","cvss":[{"version":"4.0","score":6.9,"vector":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:P/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"medium"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high"}],"cwes":["CWE-321"],"updated_at":"2026-11-02T15:10:11.66732Z"}],"nvd":[{"id":"CVE-2025-15627","description":"A cryptographic\nweakness exists in the Omada adoption protocol. \nThe protocol relies on hard-coded cryptographic keys to establish trust and\nprotect authentication exchanges between controllers and managed devices during\ndevice adoption.\n\n\n\n\n\n\n\n\n\nAn attacker may\nbe able to impersonate trusted controllers or managed devices and gain access\nto sensitive adoption-related communications.","status":"published","published":"2026-08-03T19:16:40.407Z","modified":"2026-09-29T14:10:00.117Z","cvss":[{"version":"4.0","score":6.9,"vector":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:P/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"medium","assessor":"secondary"},{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"high","assessor":"primary"}],"cwes":["CWE-321"],"updated_at":"2026-11-02T14:12:03.20248Z"}]}}