{"id":"CVE-2025-20912","aliases":["EUVD-2025-6128","GHSA-w82f-ppmw-v55m"],"status":"published","title":"Incorrect default permission in DiagMonAgent prior to SMR Mar-2025 Release 1 allows local...","description":"Incorrect default permission in DiagMonAgent prior to SMR Mar-2025 Release 1 allows local attackers to access data within Galaxy Watch.","severity":{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00154,"percentile":0.04589,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-922"],"published":"2025-03-06T05:04:14Z","modified":"2026-06-17T08:42:11Z","products":[{"vendor":"samsung","product":"wear_os"},{"vendor":"samsung mobile","product":"samsung mobile devices"}],"references":[{"url":"https://security.samsungmobile.com/securityUpdate.smsb?year=2025\u0026month=03","tags":["Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-20912"},{"url":"https://github.com/advisories/GHSA-w82f-ppmw-v55m"}],"sources":{"cve":[{"id":"CVE-2025-20912","description":"Incorrect default permission in DiagMonAgent prior to SMR Mar-2025 Release 1 allows local attackers to access data within Galaxy Watch.","status":"published","published":"2025-03-06T05:04:14.721Z","modified":"2025-03-06T15:02:16.548Z","cvss":[{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"cna"}],"updated_at":"2026-11-02T14:32:25.5658Z"}],"euvd":[{"id":"EUVD-2025-6128","description":"Incorrect default permission in DiagMonAgent prior to SMR Mar-2025 Release 1 allows local attackers to access data within Galaxy Watch.","status":"published","published":"2025-03-06T05:04:14Z","modified":"2025-03-06T15:02:16Z","cvss":[{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium"}],"updated_at":"2026-11-02T20:53:11.47787Z"}],"ghsa":[{"id":"GHSA-w82f-ppmw-v55m","title":"Incorrect default permission in DiagMonAgent prior to SMR Mar-2025 Release 1 allows local...","description":"Incorrect default permission in DiagMonAgent prior to SMR Mar-2025 Release 1 allows local attackers to access data within Galaxy Watch.","status":"published","published":"2025-03-06T06:30:52Z","modified":"2026-02-02T18:31:28Z","cvss":[{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium"}],"cwes":["CWE-922"],"updated_at":"2026-11-02T15:06:00.246323Z"}],"nvd":[{"id":"CVE-2025-20912","description":"Incorrect default permission in DiagMonAgent prior to SMR Mar-2025 Release 1 allows local attackers to access data within Galaxy Watch.","status":"published","published":"2025-03-06T05:15:17.86Z","modified":"2026-06-17T08:42:11.583Z","cvss":[{"version":"3.1","score":6.2,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"secondary"}],"cwes":["CWE-922"],"updated_at":"2026-11-02T14:10:53.101324Z"}]}}
