{"id":"CVE-2025-27211","aliases":["EUVD-2025-23555","GHSA-p4c7-7c56-gxgj"],"status":"published","title":"An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a...","description":"An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.","severity":{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"adp","from":"cve"},"epss":{"day":"2026-11-10","score":0.00514,"percentile":0.44103,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-20","CWE-77"],"published":"2025-08-04T22:12:18Z","modified":"2026-06-17T09:03:12Z","products":[{"vendor":"ubiquiti inc","product":"edgemax edgeswitch"}],"references":[{"url":"https://community.ui.com/releases/Security-Advisory-Bulletin-050-050/f82b1701-58a1-4b7d-9e20-82d50e3e1961"},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-27211"},{"url":"https://github.com/advisories/GHSA-p4c7-7c56-gxgj"}],"sources":{"cve":[{"id":"CVE-2025-27211","description":"An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.","status":"published","published":"2025-08-04T22:12:18.821Z","modified":"2025-08-05T13:26:05.845Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"adp"}],"cwes":["CWE-20","CWE-77"],"updated_at":"2026-11-02T14:32:42.078906Z"}],"euvd":[{"id":"EUVD-2025-23555","description":"An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.","status":"published","published":"2025-08-04T22:12:18Z","modified":"2025-08-05T13:26:05Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-02T20:32:01.599514Z"}],"ghsa":[{"id":"GHSA-p4c7-7c56-gxgj","title":"An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a...","description":"An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.","status":"published","published":"2025-08-05T00:30:26Z","modified":"2025-08-05T15:31:46Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-20"],"updated_at":"2026-11-02T15:03:11.278533Z"}],"nvd":[{"id":"CVE-2025-27211","description":"An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.","status":"published","published":"2025-08-04T23:15:27.403Z","modified":"2026-06-17T09:03:12.947Z","cvss":[{"version":"3.1","score":7.5,"vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"}],"cwes":["CWE-20","CWE-77"],"updated_at":"2026-11-02T14:11:22.319351Z"}]}}
