{"id":"CVE-2025-30421","aliases":["EUVD-2025-15181","GHSA-5ppx-9rrh-j4wr"],"status":"published","title":"Stack-based Buffer Overflow in DrObjectStorage::XML_Serialize() in NI Circuit Design Suite","description":"There is a memory corruption vulnerability due to a stack-based buffer overflow in DrObjectStorage::XML_Serialize() when using the SymbolEditor in NI Circuit Design Suite.  This vulnerability may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .sym file. This vulnerability affects NI Circuit Design Suite 14.3.0 and prior versions.","severity":{"version":"4.0","score":8.5,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00207,"percentile":0.10858,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-121","CWE-787"],"published":"2025-05-15T16:32:33Z","modified":"2026-06-17T09:08:41Z","products":[{"vendor":"ni","product":"circuit design suite"},{"vendor":"ni","product":"circuit_design_suite"}],"references":[{"url":"https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-vulnerabilities-in-ni-circuit-design-suite.html","tags":["Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-30421"},{"url":"https://github.com/advisories/GHSA-5ppx-9rrh-j4wr"}],"sources":{"cve":[{"id":"CVE-2025-30421","title":"Stack-based Buffer Overflow in DrObjectStorage::XML_Serialize() in NI Circuit Design Suite","description":"There is a memory corruption vulnerability due to a stack-based buffer overflow in DrObjectStorage::XML_Serialize() when using the SymbolEditor in NI Circuit Design Suite.  This vulnerability may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .sym file. This vulnerability affects NI Circuit Design Suite 14.3.0 and prior versions.","status":"published","published":"2025-05-15T16:32:33.387Z","modified":"2025-05-15T19:37:17.92Z","cvss":[{"version":"4.0","score":8.5,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"high","assessor":"cna"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"}],"cwes":["CWE-121"],"updated_at":"2026-11-02T14:32:35.418416Z"}],"euvd":[{"id":"EUVD-2025-15181","description":"There is a memory corruption vulnerability due to a stack-based buffer overflow in DrObjectStorage::XML_Serialize() when using the SymbolEditor in NI Circuit Design Suite.  This vulnerability may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .sym file. This vulnerability affects NI Circuit Design Suite 14.3.0 and prior versions.","status":"published","published":"2025-05-15T16:32:33Z","modified":"2025-05-15T19:37:17Z","cvss":[{"version":"4.0","score":8.5,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"high"}],"updated_at":"2026-11-02T20:32:46.094311Z"}],"ghsa":[{"id":"GHSA-5ppx-9rrh-j4wr","title":"There is a memory corruption vulnerability due to a stack-based buffer overflow in...","description":"There is a memory corruption vulnerability due to a stack-based buffer overflow in DrObjectStorage::XML_Serialize() when using the SymbolEditor in NI Circuit Design Suite.  This vulnerability may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .sym file. This vulnerability affects NI Circuit Design Suite 14.3.0 and prior versions.","status":"published","published":"2025-05-15T18:31:47Z","modified":"2025-05-20T18:30:52Z","cvss":[{"version":"4.0","score":8.5,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-121","CWE-787"],"updated_at":"2026-11-02T15:02:22.425596Z"}],"nvd":[{"id":"CVE-2025-30421","description":"There is a memory corruption vulnerability due to a stack-based buffer overflow in DrObjectStorage::XML_Serialize() when using the SymbolEditor in NI Circuit Design Suite.  This vulnerability may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .sym file. This vulnerability affects NI Circuit Design Suite 14.3.0 and prior versions.","status":"published","published":"2025-05-15T17:15:54.133Z","modified":"2026-06-17T09:08:41.643Z","cvss":[{"version":"4.0","score":8.5,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high","assessor":"secondary"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"primary"}],"cwes":["CWE-121","CWE-787"],"updated_at":"2026-11-02T14:11:08.321805Z"}]}}