{"id":"CVE-2025-54167","aliases":["EUVD-2025-38276","GHSA-rp6p-wfxv-r42f"],"status":"published","title":"Notification Center","description":"A cross-site scripting (XSS) vulnerability has been reported to affect Notification Center. If a remote attacker gains an administrator account, they can then exploit the vulnerability to bypass security mechanisms or read application data.\n\nWe have already fixed the vulnerability in the following versions:\nNotification Center 2.1.0.3443 and later\nNotification Center 1.9.2.3163 and later\nNotification Center 3.0.0.3466 and later","severity":{"version":"4.0","score":7.2,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N/E:U","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00534,"percentile":0.45529,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-79"],"published":"2025-11-07T15:12:39Z","modified":"2026-10-18T21:10:00Z","products":[{"vendor":"qnap systems inc.","product":"notification center"}],"references":[{"url":"https://www.qnap.com/en/security-advisory/qsa-25-40"},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-54167"},{"url":"https://github.com/advisories/GHSA-rp6p-wfxv-r42f"}],"sources":{"cve":[{"id":"CVE-2025-54167","title":"Notification Center","description":"A cross-site scripting (XSS) vulnerability has been reported to affect Notification Center. If a remote attacker gains an administrator account, they can then exploit the vulnerability to bypass security mechanisms or read application data.\n\nWe have already fixed the vulnerability in the following versions:\nNotification Center 2.1.0.3443 and later\nNotification Center 1.9.2.3163 and later\nNotification Center 3.0.0.3466 and later","status":"published","published":"2025-11-07T15:12:39.176Z","modified":"2025-11-07T15:57:14.662Z","cvss":[{"version":"4.0","score":7.2,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N/E:U","level":"high","assessor":"cna"}],"cwes":["CWE-79"],"updated_at":"2026-11-02T14:32:27.603809Z"}],"euvd":[{"id":"EUVD-2025-38276","description":"A cross-site scripting (XSS) vulnerability has been reported to affect Notification Center. If a remote attacker gains an administrator account, they can then exploit the vulnerability to bypass security mechanisms or read application data.\n\nWe have already fixed the vulnerability in the following versions:\nNotification Center 2.1.0.3443 and later\nNotification Center 1.9.2.3163 and later\nNotification Center 3.0.0.3466 and later","status":"published","published":"2025-11-07T15:12:39Z","modified":"2025-11-07T15:57:14Z","cvss":[{"version":"4.0","score":7.2,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N/E:U","level":"high"}],"updated_at":"2026-11-02T19:49:19.321345Z"}],"ghsa":[{"id":"GHSA-rp6p-wfxv-r42f","title":"A cross-site scripting (XSS) vulnerability has been reported to affect Notification Center. If a...","description":"A cross-site scripting (XSS) vulnerability has been reported to affect Notification Center. If a remote attacker gains an administrator account, they can then exploit the vulnerability to bypass security mechanisms or read application data.\n\nWe have already fixed the vulnerability in the following versions:\nNotification Center 2.1.0.3443 and later\nNotification Center 1.9.2.3163 and later\nNotification Center 3.0.0.3466 and later","status":"published","published":"2025-11-07T18:30:29Z","modified":"2025-11-07T18:30:37Z","cvss":[{"version":"4.0","score":7.2,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high"}],"cwes":["CWE-79"],"updated_at":"2026-11-02T15:04:42.481044Z"}],"nvd":[{"id":"CVE-2025-54167","description":"A cross-site scripting (XSS) vulnerability has been reported to affect Notification Center. If a remote attacker gains an administrator account, they can then exploit the vulnerability to bypass security mechanisms or read application data.\n\nWe have already fixed the vulnerability in the following versions:\nNotification Center 2.1.0.3443 and later\nNotification Center 1.9.2.3163 and later\nNotification Center 3.0.0.3466 and later","status":"published","published":"2025-11-07T16:15:40.1Z","modified":"2026-10-18T21:10:00.12Z","cvss":[{"version":"4.0","score":7.2,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high","assessor":"secondary"}],"cwes":["CWE-79"],"updated_at":"2026-11-02T14:11:42.870953Z"}]}}