{"id":"CVE-2025-70161","aliases":["EUVD-2026-1713","GHSA-44vp-c93r-6656"],"status":"published","title":"EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName...","description":"EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName field is directly passed to a shell command via the system() function without proper sanitization. An attacker can exploit this by injecting malicious commands into the pppUserName field, allowing arbitrary code execution.","severity":{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"adp","from":"cve"},"epss":{"day":"2026-11-10","score":0.27062,"percentile":0.9806,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-77"],"published":"2026-01-09T00:00:00Z","modified":"2026-06-17T10:03:10Z","products":[{"vendor":"edimax","product":"br-6208ac_firmware"}],"references":[{"url":"https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-setWAN-handler-2d3b5c52018a80d7ae8dce2bf5e3294c?source=copy_link","tags":["Exploit","Third Party Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2025-70161"},{"url":"https://github.com/advisories/GHSA-44vp-c93r-6656"}],"sources":{"cve":[{"id":"CVE-2025-70161","description":"EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName field is directly passed to a shell command via the system() function without proper sanitization. An attacker can exploit this by injecting malicious commands into the pppUserName field, allowing arbitrary code execution.","status":"published","published":"2026-01-09T00:00:00Z","modified":"2026-01-12T16:24:37.524Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"adp"}],"cwes":["CWE-77"],"updated_at":"2026-11-02T14:32:25.186422Z"}],"euvd":[{"id":"EUVD-2026-1713","description":"EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName field is directly passed to a shell command via the system() function without proper sanitization. An attacker can exploit this by injecting malicious commands into the pppUserName field, allowing arbitrary code execution.","status":"published","published":"2026-01-09T00:00:00Z","modified":"2026-01-12T16:24:37Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"updated_at":"2026-11-02T19:48:53.623536Z"}],"ghsa":[{"id":"GHSA-44vp-c93r-6656","title":"EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName...","description":"EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName field is directly passed to a shell command via the system() function without proper sanitization. An attacker can exploit this by injecting malicious commands into the pppUserName field, allowing arbitrary code execution.","status":"published","published":"2026-01-09T18:31:37Z","modified":"2026-01-12T18:31:31Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical"}],"cwes":["CWE-77"],"updated_at":"2026-11-02T15:05:34.043335Z"}],"nvd":[{"id":"CVE-2025-70161","description":"EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName field is directly passed to a shell command via the system() function without proper sanitization. An attacker can exploit this by injecting malicious commands into the pppUserName field, allowing arbitrary code execution.","status":"published","published":"2026-01-09T17:15:54.247Z","modified":"2026-06-17T10:03:10.99Z","cvss":[{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"secondary"}],"cwes":["CWE-77"],"updated_at":"2026-11-02T14:11:56.616231Z"}]}}
