{"id":"CVE-2026-0975","aliases":["EUVD-2026-2977","GHSA-7xx5-w679-mjw9"],"status":"published","title":"DIAView - Command Injection Vulnerability","description":"Delta Electronics DIAView has Command Injection vulnerability.","severity":{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-10","score":0.01512,"percentile":0.7468,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-77"],"published":"2026-01-16T06:01:59Z","modified":"2026-06-17T10:11:43Z","products":[{"vendor":"delta electronics","product":"diaview"},{"vendor":"deltaww","product":"diaview"}],"references":[{"url":"https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00002_DIAView%20-Exposed%20Dangerous%20Method%20Remote%20Code%20Execution%20(CVE-2026-0975).pdf","tags":["Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-0975"},{"url":"https://github.com/advisories/GHSA-7xx5-w679-mjw9"}],"sources":{"cve":[{"id":"CVE-2026-0975","title":"DIAView - Command Injection Vulnerability","description":"Delta Electronics DIAView has Command Injection vulnerability.","status":"published","published":"2026-01-16T06:01:59.903Z","modified":"2026-01-16T14:00:54.208Z","cvss":[{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"cna"}],"cwes":["CWE-77"],"updated_at":"2026-11-02T14:20:13.587351Z"}],"euvd":[{"id":"EUVD-2026-2977","description":"Delta Electronics DIAView has Command Injection vulnerability.","status":"published","published":"2026-01-16T06:01:59Z","modified":"2026-01-16T14:00:54Z","cvss":[{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high"}],"updated_at":"2026-11-02T19:48:50.882066Z"}],"ghsa":[{"id":"GHSA-7xx5-w679-mjw9","title":"Delta Electronics DIAView has Command Injection vulnerability.","description":"Delta Electronics DIAView has Command Injection vulnerability.","status":"published","published":"2026-01-16T06:30:15Z","modified":"2026-01-16T06:30:16Z","cvss":[{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-77"],"updated_at":"2026-11-02T15:05:38.149378Z"}],"nvd":[{"id":"CVE-2026-0975","description":"Delta Electronics DIAView has Command Injection vulnerability.","status":"published","published":"2026-01-16T06:15:51.187Z","modified":"2026-06-17T10:11:43.103Z","cvss":[{"version":"3.1","score":7.8,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"3.1","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","level":"critical","assessor":"primary"}],"cwes":["CWE-77"],"updated_at":"2026-11-02T14:12:04.066712Z"}]}}
