{"id":"CVE-2026-100130","aliases":["EUVD-2026-100694","GHSA-vqcv-8w4v-jw58"],"status":"published","title":"Substance3D - Sampler | Out-of-bounds Read (CWE-125)","description":"Substance3D - Sampler is affected by an out-of-bounds read vulnerability that could lead to disclosure of sensitive memory. An attacker could leverage this vulnerability to disclose sensitive information. Exploitation of this issue requires user interaction in that a victim must open a malicious file.","severity":{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","level":"medium","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00144,"percentile":0.03766,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-125"],"published":"2026-10-13T20:31:37Z","modified":"2026-11-09T22:25:39Z","products":[{"vendor":"adobe","product":"substance 3d sampler"},{"vendor":"adobe","product":"substance_3d_sampler"}],"references":[{"url":"https://www.adobe.com/trust/security/products/substance3d-sampler/apsb26-159.html","tags":["vendor-advisory","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-100130"},{"url":"https://github.com/advisories/GHSA-vqcv-8w4v-jw58"}],"sources":{"cve":[{"id":"CVE-2026-100130","title":"Substance3D - Sampler | Out-of-bounds Read (CWE-125)","description":"Substance3D - Sampler is affected by an out-of-bounds read vulnerability that could lead to disclosure of sensitive memory. An attacker could leverage this vulnerability to disclose sensitive information. Exploitation of this issue requires user interaction in that a victim must open a malicious file.","status":"published","published":"2026-10-13T20:31:37.684Z","modified":"2026-10-14T14:53:06.492Z","cvss":[{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","level":"medium","assessor":"cna"}],"cwes":["CWE-125"],"updated_at":"2026-11-02T14:20:06.925367Z"}],"euvd":[{"id":"EUVD-2026-100694","description":"Substance3D - Sampler is affected by an out-of-bounds read vulnerability that could lead to disclosure of sensitive memory. An attacker could leverage this vulnerability to disclose sensitive information. Exploitation of this issue requires user interaction in that a victim must open a malicious file.","status":"published","published":"2026-10-13T20:31:37Z","modified":"2026-10-14T14:53:06Z","cvss":[{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","level":"medium"}],"updated_at":"2026-11-02T17:27:15.108271Z"}],"ghsa":[{"id":"GHSA-vqcv-8w4v-jw58","title":"Substance3D - Sampler is affected by an out-of-bounds read vulnerability that could lead to...","description":"Substance3D - Sampler is affected by an out-of-bounds read vulnerability that could lead to disclosure of sensitive memory. An attacker could leverage this vulnerability to disclose sensitive information. Exploitation of this issue requires user interaction in that a victim must open a malicious file.","status":"published","published":"2026-10-13T21:37:26Z","modified":"2026-10-13T21:37:33Z","cvss":[{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","level":"medium"}],"cwes":["CWE-125"],"updated_at":"2026-11-02T15:13:21.557572Z"}],"nvd":[{"id":"CVE-2026-100130","description":"Substance3D - Sampler is affected by an out-of-bounds read vulnerability that could lead to disclosure of sensitive memory. An attacker could leverage this vulnerability to disclose sensitive information. Exploitation of this issue requires user interaction in that a victim must open a malicious file.","status":"published","published":"2026-10-13T21:17:15.1Z","modified":"2026-11-09T22:25:39.203Z","cvss":[{"version":"3.1","score":5.5,"vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","level":"medium","assessor":"secondary"}],"cwes":["CWE-125"],"updated_at":"2026-11-09T23:16:03.231985Z"}]}}
