{"id":"CVE-2026-108795","aliases":["EUVD-2026-97166","GHSA-gw6g-7mcq-52gh"],"status":"published","title":"ZKTeco BioTime System Settings API systemSettings access control","description":"A vulnerability was detected in ZKTeco BioTime 9.5.6 Build 20260130.3206. Affected by this issue is some unknown functionality of the file /base/api/systemSettings of the component System Settings API. Performing a manipulation results in improper access controls. The attack can be initiated remotely. Upgrading to version 9.5.6 Build 3623 can resolve this issue. It is advisable to upgrade the affected component.","severity":{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X","level":"medium","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00255,"percentile":0.17277,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-266","CWE-284"],"published":"2026-10-12T03:15:11Z","modified":"2026-10-16T15:39:20Z","products":[{"vendor":"zkteco","product":"biotime"}],"references":[{"url":"https://vuldb.com/vuln/416572","tags":["vdb-entry"]},{"url":"https://vuldb.com/vuln/416572/cti","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/cve/CVE-2026-108795","tags":["third-party-advisory"]},{"url":"https://vuldb.com/submit/961121","tags":["third-party-advisory","exploit"]},{"url":"https://www.zkteco.com/en/Security_Bulletinsibs/27","tags":["patch"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-108795"},{"url":"https://github.com/advisories/GHSA-gw6g-7mcq-52gh"}],"sources":{"cve":[{"id":"CVE-2026-108795","title":"ZKTeco BioTime System Settings API systemSettings access control","description":"A vulnerability was detected in ZKTeco BioTime 9.5.6 Build 20260130.3206. Affected by this issue is some unknown functionality of the file /base/api/systemSettings of the component System Settings API. Performing a manipulation results in improper access controls. The attack can be initiated remotely. Upgrading to version 9.5.6 Build 3623 can resolve this issue. It is advisable to upgrade the affected component.","status":"published","published":"2026-10-12T03:15:11.391Z","modified":"2026-10-16T12:45:42.116Z","cvss":[{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X","level":"medium","assessor":"cna"},{"version":"3.1","score":4.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:X/RL:O/RC:C","level":"medium","assessor":"cna"},{"version":"3.0","score":4.3,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:X/RL:O/RC:C","level":"medium","assessor":"cna"},{"version":"2.0","score":4,"vector":"AV:N/AC:L/Au:S/C:P/I:N/A:N/E:ND/RL:OF/RC:C","assessor":"cna"}],"cwes":["CWE-284","CWE-266"],"updated_at":"2026-11-02T14:20:10.143031Z"}],"euvd":[{"id":"EUVD-2026-97166","description":"A vulnerability was detected in ZKTeco BioTime 9.5.6 Build 20260130.3206. Affected by this issue is some unknown functionality of the file /base/api/systemSettings of the component System Settings API. Performing a manipulation results in improper access controls. The attack can be initiated remotely. Upgrading to version 9.5.6 Build 3623 can resolve this issue. It is advisable to upgrade the affected component.","status":"published","published":"2026-10-12T03:15:11Z","modified":"2026-10-16T12:45:42Z","cvss":[{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X","level":"medium"}],"updated_at":"2026-11-02T17:00:06.126239Z"}],"ghsa":[{"id":"GHSA-gw6g-7mcq-52gh","title":"A vulnerability was detected in ZKTeco BioTime 9.5.6 Build 20260130.3206. Affected by this issue...","description":"A vulnerability was detected in ZKTeco BioTime 9.5.6 Build 20260130.3206. Affected by this issue is some unknown functionality of the file /base/api/systemSettings of the component System Settings API. Performing a manipulation results in improper access controls. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way.","status":"published","published":"2026-10-12T06:31:14Z","modified":"2026-10-16T15:39:20Z","cvss":[{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"medium"},{"version":"3.1","score":4.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","level":"medium"}],"cwes":["CWE-266"],"updated_at":"2026-11-02T15:13:51.736258Z"}],"nvd":[{"id":"CVE-2026-108795","description":"A vulnerability was detected in ZKTeco BioTime 9.5.6 Build 20260130.3206. Affected by this issue is some unknown functionality of the file /base/api/systemSettings of the component System Settings API. Performing a manipulation results in improper access controls. The attack can be initiated remotely. Upgrading to version 9.5.6 Build 3623 can resolve this issue. It is advisable to upgrade the affected component.","status":"published","published":"2026-10-12T04:16:43.58Z","modified":"2026-10-16T13:16:54.35Z","cvss":[{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"medium","assessor":"secondary"},{"version":"3.1","score":4.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","level":"medium","assessor":"secondary"},{"version":"2.0","score":4,"vector":"AV:N/AC:L/Au:S/C:P/I:N/A:N","level":"medium","assessor":"secondary"}],"cwes":["CWE-266","CWE-284"],"updated_at":"2026-11-02T14:12:56.310333Z"}]}}