{"id":"CVE-2026-1226","aliases":["EUVD-2026-7074","GHSA-9vw9-245h-4g2j"],"status":"published","title":"CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of...","description":"CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file.","severity":{"version":"4.0","score":7,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00154,"percentile":0.04633,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-94"],"published":"2026-02-11T13:49:45Z","modified":"2026-06-17T10:15:21Z","products":[{"vendor":"schneider eelctric","product":"ecostruxure building operation workstation"},{"vendor":"schneider electric","product":"ecostruxure building operation webstation"},{"vendor":"schneider electric","product":"ecostruxure building operation workstation"}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-041-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2026-041-02.pdf"},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-1226"},{"url":"https://github.com/advisories/GHSA-9vw9-245h-4g2j"}],"sources":{"cve":[{"id":"CVE-2026-1226","description":"CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file.","status":"published","published":"2026-02-11T13:49:45.465Z","modified":"2026-02-11T14:07:27.708Z","cvss":[{"version":"4.0","score":7,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"high","assessor":"cna"}],"cwes":["CWE-94"],"updated_at":"2026-11-02T14:20:01.271368Z"}],"euvd":[{"id":"EUVD-2026-7074","description":"CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file.","status":"published","published":"2026-02-11T13:49:45Z","modified":"2026-02-11T14:07:27Z","cvss":[{"version":"4.0","score":7,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","level":"high"}],"updated_at":"2026-11-02T19:48:41.30503Z"}],"ghsa":[{"id":"GHSA-9vw9-245h-4g2j","title":"CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of...","description":"CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file.","status":"published","published":"2026-02-11T15:30:27Z","modified":"2026-02-11T15:30:33Z","cvss":[{"version":"4.0","score":7,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high"}],"cwes":["CWE-94"],"updated_at":"2026-11-02T15:06:09.03825Z"}],"nvd":[{"id":"CVE-2026-1226","description":"CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file.","status":"published","published":"2026-02-11T14:16:01.973Z","modified":"2026-06-17T10:15:21.49Z","cvss":[{"version":"4.0","score":7,"vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high","assessor":"secondary"}],"cwes":["CWE-94"],"updated_at":"2026-11-02T14:12:05.908608Z"}]}}
