{"id":"CVE-2026-22078","aliases":["EUVD-2026-40052","GHSA-xf9v-h779-xxhr"],"status":"published","title":"O+ Connect's lack of authentication for IPC channels led to a local privilege escalation vulnerability.","description":"Because O+ Connect's IPC service does not authenticate clients, external applications can escalate privileges and perform sensitive actions through the IPC channel.","severity":{"version":"3.1","score":7.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:H","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00122,"percentile":0.02026,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-266"],"published":"2026-06-29T08:05:49Z","modified":"2026-10-25T17:10:00Z","products":[{"vendor":"oppo","product":"o+ connect"}],"references":[{"url":"https://security.oppo.com/en/noticeDetail?notice_only_key=NOTICE-2070415238859333632"},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-22078"},{"url":"https://github.com/advisories/GHSA-xf9v-h779-xxhr"}],"sources":{"cve":[{"id":"CVE-2026-22078","title":"O+ Connect's lack of authentication for IPC channels led to a local privilege escalation vulnerability.","description":"Because O+ Connect's IPC service does not authenticate clients, external applications can escalate privileges and perform sensitive actions through the IPC channel.","status":"published","published":"2026-06-29T08:05:49.776Z","modified":"2026-06-29T11:53:21.664Z","cvss":[{"version":"3.1","score":7.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:H","level":"high","assessor":"cna"}],"cwes":["CWE-266"],"updated_at":"2026-11-02T13:39:16.730222Z"}],"euvd":[{"id":"EUVD-2026-40052","description":"Because O+ Connect's IPC service does not authenticate clients, external applications can escalate privileges and perform sensitive actions through the IPC channel.","status":"published","published":"2026-06-29T08:05:49Z","modified":"2026-06-29T11:53:21Z","cvss":[{"version":"3.1","score":7.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:H","level":"high"}],"updated_at":"2026-11-02T18:20:23.349194Z"}],"ghsa":[{"id":"GHSA-xf9v-h779-xxhr","title":"Because O+ Connect's IPC service does not authenticate clients, external applications can...","description":"Because O+ Connect's IPC service does not authenticate clients, external applications can escalate privileges and perform sensitive actions through the IPC channel.","status":"published","published":"2026-06-29T09:30:29Z","modified":"2026-06-29T09:30:37Z","cvss":[{"version":"3.1","score":7.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:H","level":"high"}],"cwes":["CWE-266"],"updated_at":"2026-11-02T15:09:03.268343Z"}],"nvd":[{"id":"CVE-2026-22078","description":"Because O+ Connect's IPC service does not authenticate clients, external applications can escalate privileges and perform sensitive actions through the IPC channel.","status":"published","published":"2026-06-29T09:16:28.44Z","modified":"2026-10-25T17:10:00.197Z","cvss":[{"version":"3.1","score":7.3,"vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:H","level":"high","assessor":"secondary"}],"cwes":["CWE-266"],"updated_at":"2026-11-02T14:12:26.508751Z"}]}}
