{"id":"CVE-2026-2908","aliases":["EUVD-2026-7540","GHSA-2665-m8rg-c7xp"],"status":"published","title":"Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow","description":"A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.","severity":{"version":"4.0","score":8.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-12","score":0.00646,"percentile":0.51477,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-119","CWE-121"],"published":"2026-02-22T02:02:10Z","modified":"2026-06-17T10:32:00Z","products":[{"vendor":"tenda","product":"hg9"},{"vendor":"tenda","product":"hg9_firmware"}],"references":[{"url":"https://vuldb.com/?id.347217","tags":["vdb-entry","technical-description","Third Party Advisory","VDB Entry"]},{"url":"https://vuldb.com/?ctiid.347217","tags":["signature","permissions-required","Permissions Required","VDB Entry"]},{"url":"https://vuldb.com/?submit.755202","tags":["third-party-advisory","Third Party Advisory","VDB Entry"]},{"url":"https://github.com/QIU-DIE/cve-nneeww/issues/10","tags":["exploit","issue-tracking","Exploit","Issue Tracking","Mitigation","Third Party Advisory"]},{"url":"https://www.tenda.com.cn/","tags":["product","Product"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-2908"},{"url":"https://www.tenda.com.cn"},{"url":"https://github.com/advisories/GHSA-2665-m8rg-c7xp"}],"sources":{"cve":[{"id":"CVE-2026-2908","title":"Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow","description":"A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.","status":"published","published":"2026-02-22T02:02:10.921Z","modified":"2026-02-23T19:19:51.049Z","cvss":[{"version":"4.0","score":8.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","level":"high","assessor":"cna"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R","level":"high","assessor":"cna"},{"version":"3.0","score":8.8,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R","level":"high","assessor":"cna"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR","assessor":"cna"}],"cwes":["CWE-121","CWE-119"],"updated_at":"2026-11-02T13:48:35.749498Z"}],"euvd":[{"id":"EUVD-2026-7540","description":"A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.","status":"published","published":"2026-02-22T02:02:10Z","modified":"2026-02-23T19:19:51Z","cvss":[{"version":"4.0","score":8.7,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","level":"high"}],"updated_at":"2026-11-02T19:48:32.158773Z"}],"ghsa":[{"id":"GHSA-2665-m8rg-c7xp","title":"A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some...","description":"A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.","status":"published","published":"2026-02-22T03:30:26Z","modified":"2026-02-22T03:30:33Z","cvss":[{"version":"4.0","score":7.4,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high"}],"cwes":["CWE-119"],"updated_at":"2026-11-02T15:06:18.587191Z"}],"nvd":[{"id":"CVE-2026-2908","description":"A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.","status":"published","published":"2026-02-22T02:16:57.89Z","modified":"2026-06-17T10:32:00.85Z","cvss":[{"version":"4.0","score":7.4,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high","assessor":"secondary"},{"version":"3.1","score":8.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","level":"high","assessor":"secondary"},{"version":"2.0","score":9,"vector":"AV:N/AC:L/Au:S/C:C/I:C/A:C","level":"high","assessor":"secondary"}],"cwes":["CWE-119","CWE-121"],"updated_at":"2026-11-02T14:12:06.63895Z"}]}}