{"id":"CVE-2026-77975","aliases":["EUVD-2026-68609","GHSA-mfqx-v89r-g539"],"status":"published","title":"Ebyte NA111-M Cleartext Storage of Sensitive Information","description":"The affected Ebyte \n\nproduct exports administrative credentials and other \nsensitive configuration information without adequate protection. An \nunauthenticated attacker on the adjacent network who can obtain an \nexported configuration file could recover valid credentials and use them\n to access the device or similarly configured systems.","severity":{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","level":"high","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.00181,"percentile":0.07809,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-312"],"published":"2026-08-31T15:26:08Z","modified":"2026-10-05T19:27:44Z","products":[{"vendor":"ebyte","product":"ebyte ne2-d11 firmware"}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-237-06"},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-237-06.json"},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-77975"},{"url":"https://github.com/advisories/GHSA-mfqx-v89r-g539"}],"sources":{"cve":[{"id":"CVE-2026-77975","title":"Ebyte NA111-M Cleartext Storage of Sensitive Information","description":"The affected Ebyte \n\nproduct exports administrative credentials and other \nsensitive configuration information without adequate protection. An \nunauthenticated attacker on the adjacent network who can obtain an \nexported configuration file could recover valid credentials and use them\n to access the device or similarly configured systems.","status":"published","published":"2026-08-31T15:26:08.482Z","modified":"2026-10-05T19:27:44.696Z","cvss":[{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","level":"high","assessor":"cna"},{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"cna"}],"cwes":["CWE-312"],"updated_at":"2026-11-02T14:20:16.072351Z"}],"euvd":[{"id":"EUVD-2026-68609","description":"The affected Ebyte \n\nproduct exports administrative credentials and other \nsensitive configuration information without adequate protection. An \nunauthenticated attacker on the adjacent network who can obtain an \nexported configuration file could recover valid credentials and use them\n to access the device or similarly configured systems.","status":"published","published":"2026-08-31T15:26:08Z","modified":"2026-10-05T19:27:44Z","cvss":[{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","level":"high"}],"updated_at":"2026-11-02T17:27:39.05741Z"}],"ghsa":[{"id":"GHSA-mfqx-v89r-g539","title":"The affected Ebyte \n\nproduct exports administrative credentials and other \nsensitive...","description":"The affected Ebyte \n\nproduct exports administrative credentials and other \nsensitive configuration information without adequate protection. An \nunauthenticated attacker on the adjacent network who can obtain an \nexported configuration file could recover valid credentials and use them\n to access the device or similarly configured systems.","status":"published","published":"2026-08-31T18:31:29Z","modified":"2026-08-31T18:31:39Z","cvss":[{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high"},{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium"}],"cwes":["CWE-312"],"updated_at":"2026-11-02T15:11:11.962153Z"}],"nvd":[{"id":"CVE-2026-77975","description":"The affected Ebyte \n\nproduct exports administrative credentials and other \nsensitive configuration information without adequate protection. An \nunauthenticated attacker on the adjacent network who can obtain an \nexported configuration file could recover valid credentials and use them\n to access the device or similarly configured systems.","status":"published","published":"2026-08-31T16:19:13.19Z","modified":"2026-09-01T17:17:35.243Z","cvss":[{"version":"4.0","score":7.1,"vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"high","assessor":"secondary"},{"version":"3.1","score":6.5,"vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"secondary"}],"cwes":["CWE-312"],"updated_at":"2026-11-02T14:12:42.691315Z"}]}}