{"id":"CVE-2026-81049","aliases":["EUVD-2026-75566","GHSA-94cm-x3qr-35xh"],"status":"published","title":"Dell ThinOS 10, versions prior to 2605_10.2616, contain a Missing Support for Integrity Check...","description":"Dell ThinOS 10, versions prior to 2605_10.2616, contain a Missing Support for Integrity Check vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution.","severity":{"version":"3.1","score":4.4,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-09","score":0.00119,"percentile":0.01791,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-353"],"published":"2026-09-10T15:39:07Z","modified":"2026-11-03T22:13:33Z","products":[{"vendor":"dell","product":"thinos"},{"vendor":"dell","product":"thinos 10"}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000502746/dsa-2026-389-security-update-for-dell-thinos-10-for-multiple-vulnerabilities","tags":["vendor-advisory","Vendor Advisory"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-81049"},{"url":"https://github.com/advisories/GHSA-94cm-x3qr-35xh"}],"sources":{"cve":[{"id":"CVE-2026-81049","description":"Dell ThinOS 10, versions prior to 2605_10.2616, contain a Missing Support for Integrity Check vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution.","status":"published","published":"2026-09-10T15:39:07.163Z","modified":"2026-11-03T22:13:33.229Z","cvss":[{"version":"3.1","score":4.4,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"cna"}],"cwes":["CWE-353"],"updated_at":"2026-11-03T23:33:09.822755Z"}],"euvd":[{"id":"EUVD-2026-75566","description":"Dell ThinOS 10, versions prior to 2605_10.2616, contain a Missing Support for Integrity Check vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution.","status":"published","published":"2026-09-10T15:39:07Z","modified":"2026-11-03T22:13:33Z","cvss":[{"version":"3.1","score":4.4,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","level":"medium"}],"updated_at":"2026-11-03T23:01:34.013136Z"}],"ghsa":[{"id":"GHSA-94cm-x3qr-35xh","title":"Dell ThinOS 10, versions prior to 2605_10.2616, contain a Missing Support for Integrity Check...","description":"Dell ThinOS 10, versions prior to 2605_10.2616, contain a Missing Support for Integrity Check vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution.","status":"published","published":"2026-09-10T18:31:45Z","modified":"2026-09-10T18:32:56Z","cvss":[{"version":"3.1","score":4.4,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","level":"medium"}],"cwes":["CWE-353"],"updated_at":"2026-11-02T15:11:42.667371Z"}],"nvd":[{"id":"CVE-2026-81049","description":"Dell ThinOS 10, versions prior to 2605_10.2616, contain a Missing Support for Integrity Check vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution.","status":"published","published":"2026-09-10T16:17:57.67Z","modified":"2026-11-03T23:17:56.61Z","cvss":[{"version":"3.1","score":4.4,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","level":"medium","assessor":"secondary"},{"version":"3.1","score":6.7,"vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","level":"medium","assessor":"primary"}],"cwes":["CWE-353"],"updated_at":"2026-11-04T01:48:35.373435Z"}]}}