{"id":"CVE-2026-82595","aliases":["EUVD-2026-68298","GHSA-vh29-5rxq-8xr4"],"status":"published","title":"D-Link DIR-825M System Command Execution formSysCmd sub_456CF4 command injection","description":"A vulnerability was found in D-Link DIR-825M 1.1.8. Affected by this vulnerability is the function sub_456CF4 of the file /boafrm/formSysCmd of the component System Command Execution. Performing a manipulation of the argument sysCmd results in command injection. It is possible to initiate the attack remotely. The exploit has been made public and could be used.","severity":{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P","level":"medium","assessor":"cna","from":"cve"},"epss":{"day":"2026-11-11","score":0.04352,"percentile":0.91353,"model":"v2026.06.15"},"facts":{"in_kev":false,"known_exploited":false,"public_exploit":false,"fix_available":false},"cwes":["CWE-74","CWE-77"],"published":"2026-08-30T23:45:08Z","modified":"2026-08-31T22:17:26Z","products":[{"vendor":"d-link","product":"dir-825m"}],"references":[{"url":"https://vuldb.com/vuln/397090","tags":["vdb-entry","technical-description"]},{"url":"https://vuldb.com/vuln/397090/cti","tags":["signature","permissions-required"]},{"url":"https://vuldb.com/cve/CVE-2026-82595","tags":["third-party-advisory"]},{"url":"https://vuldb.com/submit/892630","tags":["third-party-advisory"]},{"url":"https://github.com/Robots10/IoT_vlu/blob/main/reports/Dlink/formSysCmd/formSysCmd.md","tags":["exploit"]},{"url":"https://www.dlink.com/","tags":["product"]},{"url":"https://nvd.nist.gov/vuln/detail/CVE-2026-82595"},{"url":"https://www.dlink.com"},{"url":"https://github.com/advisories/GHSA-vh29-5rxq-8xr4"}],"sources":{"cve":[{"id":"CVE-2026-82595","title":"D-Link DIR-825M System Command Execution formSysCmd sub_456CF4 command injection","description":"A vulnerability was found in D-Link DIR-825M 1.1.8. Affected by this vulnerability is the function sub_456CF4 of the file /boafrm/formSysCmd of the component System Command Execution. Performing a manipulation of the argument sysCmd results in command injection. It is possible to initiate the attack remotely. The exploit has been made public and could be used.","status":"published","published":"2026-08-30T23:45:08.885Z","modified":"2026-08-31T22:04:06.409Z","cvss":[{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P","level":"medium","assessor":"cna"},{"version":"3.1","score":7.4,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R","level":"high","assessor":"cna"},{"version":"3.0","score":7.4,"vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R","level":"high","assessor":"cna"},{"version":"2.0","score":6.5,"vector":"AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR","assessor":"cna"}],"cwes":["CWE-77","CWE-74"],"updated_at":"2026-11-02T13:40:46.161838Z"}],"euvd":[{"id":"EUVD-2026-68298","description":"A vulnerability was found in D-Link DIR-825M 1.1.8. Affected by this vulnerability is the function sub_456CF4 of the file /boafrm/formSysCmd of the component System Command Execution. Performing a manipulation of the argument sysCmd results in command injection. It is possible to initiate the attack remotely. The exploit has been made public and could be used.","status":"published","published":"2026-08-30T23:45:08Z","modified":"2026-08-31T22:04:06Z","cvss":[{"version":"4.0","score":5.3,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P","level":"medium"}],"updated_at":"2026-11-02T18:01:19.818565Z"}],"ghsa":[{"id":"GHSA-vh29-5rxq-8xr4","title":"A vulnerability was found in D-Link DIR-825M 1.1.8. Affected by this vulnerability is the...","description":"A vulnerability was found in D-Link DIR-825M 1.1.8. Affected by this vulnerability is the function sub_456CF4 of the file /boafrm/formSysCmd of the component System Command Execution. Performing a manipulation of the argument sysCmd results in command injection. It is possible to initiate the attack remotely. The exploit has been made public and could be used.","status":"published","published":"2026-08-31T00:30:21Z","modified":"2026-08-31T00:30:22Z","cvss":[{"version":"3.1","score":7.4,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L","level":"high"},{"version":"4.0","score":2.1,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"low"}],"cwes":["CWE-74"],"updated_at":"2026-11-02T15:11:10.774419Z"}],"nvd":[{"id":"CVE-2026-82595","description":"A vulnerability was found in D-Link DIR-825M 1.1.8. Affected by this vulnerability is the function sub_456CF4 of the file /boafrm/formSysCmd of the component System Command Execution. Performing a manipulation of the argument sysCmd results in command injection. It is possible to initiate the attack remotely. The exploit has been made public and could be used.","status":"published","published":"2026-08-31T00:16:41.98Z","modified":"2026-08-31T22:17:26.127Z","cvss":[{"version":"4.0","score":2.1,"vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","level":"low","assessor":"secondary"},{"version":"3.1","score":7.4,"vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L","level":"high","assessor":"secondary"},{"version":"2.0","score":6.5,"vector":"AV:N/AC:L/Au:S/C:P/I:P/A:P","level":"medium","assessor":"secondary"}],"cwes":["CWE-74","CWE-77"],"updated_at":"2026-11-02T14:12:42.691315Z"}]}}