Every CVE Search/ Get API key

CVE-2011-4879

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3...

8.5 HighPublic exploit

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.

Exploit likelihood

12.1%Up 10.7 points since Feb 4, 2022
90%50%10%1%

What each source reports

NVD Score used 8.5

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.

Record
CVE-2011-4879
CVSS 2.0
8.5 HighAV:N/AC:L/Au:N/C:P/I:N/A:C
Weakness
CWE-20
Updated
2026-11-02
CVE List No score

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.

Record
CVE-2011-4879
Updated
2026-11-02
EUVDEUVD-2011-4796 No score

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.

Record
EUVD-2011-4796
Updated
2026-11-03
GitHub AdvisoriesGHSA-m28h-wwg8-644c No score

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3...

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.

Record
GHSA-m28h-wwg8-644c
Weakness
CWE-20
Updated
2026-11-02

Affected products

Public exploits

Links only. Every CVE stores no exploit code.

Public exploits
SourceLinkDate
Exploit-DBSiemens SIMATIC WinCC Flexible (Runtime) - Multiple Vulnerabilities2011-11-28

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, Exploit-DB, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2011-4879 is a high vulnerability (CVSS 8.5) in Siemens Simatic Hmi Panels, published February 3, 2012. Public exploit code exists. EPSS puts the chance of exploitation in the next 30 days at 12.1%, the 96th percentile. No source names a fixed version.

References

Show 4 moreShow less