Every CVE Search/ Get API key

CVE-2012-0245

Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime...

10.0 High

Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via a crafted (1) 0xA or (2) 0xE Netscan packet.

Exploit likelihood

8.08%Up 0.3 points since Feb 4, 2022
90%50%10%1%

What each source reports

NVD Score used 10.0

Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via a crafted (1) 0xA or (2) 0xE Netscan packet.

Record
CVE-2012-0245
CVSS 2.0
10.0 HighAV:N/AC:L/Au:N/C:C/I:C/A:C
Weakness
CWE-119
Updated
2026-11-02
CVE List No score

Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via a crafted (1) 0xA or (2) 0xE Netscan packet.

Record
CVE-2012-0245
Updated
2026-11-02
EUVDEUVD-2012-0281 No score

Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via a crafted (1) 0xA or (2) 0xE Netscan packet.

Record
EUVD-2012-0281
Updated
2026-11-03
GitHub AdvisoriesGHSA-wh5q-r96c-q2v4 No score

Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime...

Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via a crafted (1) 0xA or (2) 0xE Netscan packet.

Record
GHSA-wh5q-r96c-q2v4
Weakness
CWE-119
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2012-0245 is a high vulnerability (CVSS 10.0) in Abb Interlink Module, published March 9, 2012. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 8.08%, the 94th percentile. No source names a fixed version.

References

MoveEnter Open