Every CVE Search/ Get API key

CVE-2012-1802

Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch...

7.8 High

Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.

Exploit likelihood

6.05%Up 1.8 points since Feb 4, 2022
90%50%10%1%

What each source reports

NVD Score used 7.8

Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.

Record
CVE-2012-1802
CVSS 2.0
7.8 HighAV:N/AC:L/Au:N/C:N/I:N/A:C
Weakness
CWE-119
Updated
2026-11-02
CVE List No score

Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.

Record
CVE-2012-1802
Updated
2026-11-02
EUVDEUVD-2012-1812 No score

Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.

Record
EUVD-2012-1812
Updated
2026-11-03
GitHub AdvisoriesGHSA-45r8-2cqp-rwrj No score

Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch...

Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.

Record
GHSA-45r8-2cqp-rwrj
Weakness
CWE-119
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2012-1802 is a high vulnerability (CVSS 7.8) in Siemens Scalance X-300, published April 18, 2012. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 6.05%, the 93rd percentile. No source names a fixed version.

References

MoveEnter Open