Every CVE Search/ Get API key

CVE-2012-2188

IBM Power Hardware Management Console (HMC) 7R3.5.0 before SP4, 7R7.1.0 and 7R7.2.0 before 7R7.2...

7.2 High

CVE-2012-2188 is a high vulnerability (CVSS 7.2) in Ibm Power Hardware Management Console Firmware, published August 6, 2012. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.35%, the 28th percentile. No source names a fixed version.

IBM Power Hardware Management Console (HMC) 7R3.5.0 before SP4, 7R7.1.0 and 7R7.2.0 before 7R7.2.0 SP3, and 7R7.3.0 before SP2, and Systems Director Management Console (SDMC) 6R7.3.0 before SP2, does not properly restrict the VIOS viosrvcmd command, which allows local users to gain privileges via vectors involving a (1) $ (dollar sign) or (2) & (ampersand) character.

Exploit likelihood

0.35%Down 0.7 points since Feb 4, 2022
90%50%10%1%

What each source reports

NVD Score used 7.2

IBM Power Hardware Management Console (HMC) 7R3.5.0 before SP4, 7R7.1.0 and 7R7.2.0 before 7R7.2.0 SP3, and 7R7.3.0 before SP2, and Systems Director Management Console (SDMC) 6R7.3.0 before SP2, does not properly restrict the VIOS viosrvcmd command, which allows local users to gain privileges via vectors involving a (1) $ (dollar sign) or (2) & (ampersand) character.

Record
CVE-2012-2188
CVSS 2.0
7.2 HighAV:L/AC:L/Au:N/C:C/I:C/A:C
Weakness
CWE-264
Updated
2026-11-02
CVE List No score

IBM Power Hardware Management Console (HMC) 7R3.5.0 before SP4, 7R7.1.0 and 7R7.2.0 before 7R7.2.0 SP3, and 7R7.3.0 before SP2, and Systems Director Management Console (SDMC) 6R7.3.0 before SP2, does not properly restrict the VIOS viosrvcmd command, which allows local users to gain privileges via vectors involving a (1) $ (dollar sign) or (2) & (ampersand) character.

Record
CVE-2012-2188
Updated
2026-11-02
EUVDEUVD-2012-2182 No score

IBM Power Hardware Management Console (HMC) 7R3.5.0 before SP4, 7R7.1.0 and 7R7.2.0 before 7R7.2.0 SP3, and 7R7.3.0 before SP2, and Systems Director Management Console (SDMC) 6R7.3.0 before SP2, does not properly restrict the VIOS viosrvcmd command, which allows local users to gain privileges via vectors involving a (1) $ (dollar sign) or (2) & (ampersand) character.

Record
EUVD-2012-2182
Updated
2026-11-03
GitHub AdvisoriesGHSA-q2w7-cc4g-wqf2 No score

IBM Power Hardware Management Console (HMC) 7R3.5.0 before SP4, 7R7.1.0 and 7R7.2.0 before 7R7.2...

IBM Power Hardware Management Console (HMC) 7R3.5.0 before SP4, 7R7.1.0 and 7R7.2.0 before 7R7.2.0 SP3, and 7R7.3.0 before SP2, and Systems Director Management Console (SDMC) 6R7.3.0 before SP2, does not properly restrict the VIOS viosrvcmd command, which allows local users to gain privileges via vectors involving a (1) $ (dollar sign) or (2) & (ampersand) character.

Record
GHSA-q2w7-cc4g-wqf2
Updated
2026-11-02

Affected products

History

History
WhenChangedSources
2026-11-03aliasesEUVD
2026-11-02createdCVE List, GitHub Advisories, NVD

References

MoveEnter Open