CVE-2014-0774
Schneider Electric OFS Stack Buffer Overflow
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.
Exploit likelihood
What each source reports
CVE List Score used
6.8
Schneider Electric OFS Stack Buffer Overflow
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.
- Record
CVE-2014-0774- CVSS 2.0
- 6.8
AV:L/AC:L/Au:S/C:C/I:C/A:C - Weakness
- CWE-121
- Updated
- 2026-11-02
EUVDEUVD-2014-0805
6.8
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.
- Record
EUVD-2014-0805- CVSS 2.0
- 6.8 Medium
AV:L/AC:L/Au:S/C:C/I:C/A:C - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-23h3-v846-4gxf No score
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server ...
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.
- Record
GHSA-23h3-v846-4gxf- Weakness
- CWE-119, CWE-121
- Updated
- 2026-11-02
NVD
6.8
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.
- Record
CVE-2014-0774- CVSS 2.0
- 6.8 Medium
AV:L/AC:L/Au:S/C:C/I:C/A:C - CVSS 2.0
- 6.9 Medium
AV:L/AC:M/Au:N/C:C/I:C/A:C - Weakness
- CWE-121, CWE-119
- Updated
- 2026-11-02
Affected products
- schneider electric tlxcdlfofs33
- schneider electric tlxcdltofs33
- schneider electric tlxcdluofs33
- schneider electric tlxcdstofs33
- schneider electric tlxcdsuofs33
- schneider-electric opc factory server
- schneider-electric ofs test client tlxcdlfofs33
- schneider-electric ofs test client tlxcdltofs33
- schneider-electric ofs test client tlxcdluofs33
- schneider-electric ofs test client tlxcdstofs33
- schneider-electric ofs test client tlxcdsuofs33
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2014-0774 is a vulnerability (CVSS 6.8) in Schneider Electric Tlxcdlfofs33, published February 28, 2014. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.47%, the 40th percentile. No source names a fixed version.