CVE-2014-9188
Schneider Electric ProClima Command Injection
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.
Exploit likelihood
What each source reports
CVE List Score used
10.0
Schneider Electric ProClima Command Injection
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.
- Record
CVE-2014-9188- CVSS 2.0
- 10.0
AV:N/AC:L/Au:N/C:C/I:C/A:C - Weakness
- CWE-77
- Updated
- 2026-11-02
EUVDEUVD-2014-9013
10.0
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.
- Record
EUVD-2014-9013- CVSS 2.0
- 10.0 Critical
AV:N/AC:L/Au:N/C:C/I:C/A:C - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-9xw9-4ffg-hrqp No score
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7...
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.
- Record
GHSA-9xw9-4ffg-hrqp- Weakness
- CWE-77, CWE-119
- Updated
- 2026-11-02
NVD
10.0
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.
- Record
CVE-2014-9188- CVSS 2.0
- 10.0 High
AV:N/AC:L/Au:N/C:C/I:C/A:C - CVSS 2.0
- 9.0 High
AV:N/AC:L/Au:N/C:C/I:P/A:P - Weakness
- CWE-77, CWE-119
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2014-9188 is a vulnerability (CVSS 10.0) in Schneider Electric Proclima, published December 27, 2014. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 6.29%, the 93rd percentile. No source names a fixed version.