Schneider Electric ETG3000 FactoryCast HMI Gateway Missing Authentication for Critical Function

10.0

The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.

Exploit likelihood

1.96%Up 0.9 points since Feb 4, 2022
90%50%10%1%

What each source reports

CVE List Score used 10.0

Schneider Electric ETG3000 FactoryCast HMI Gateway Missing Authentication for Critical Function

The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.

Record
CVE-2014-9197
CVSS 2.0
10.0 AV:N/AC:L/Au:N/C:C/I:C/A:C
Weakness
CWE-306
Updated
2026-11-02
EUVDEUVD-2014-9022 10.0

The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.

Record
EUVD-2014-9022
CVSS 2.0
10.0 CriticalAV:N/AC:L/Au:N/C:C/I:C/A:C
Updated
2026-11-02
GitHub AdvisoriesGHSA-436f-chr9-2p6r No score

The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde...

The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.

Record
GHSA-436f-chr9-2p6r
Weakness
CWE-284, CWE-306
Updated
2026-11-02
NVD 10.0

The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.

Record
CVE-2014-9197
CVSS 2.0
10.0 HighAV:N/AC:L/Au:N/C:C/I:C/A:C
CVSS 2.0
7.8 HighAV:N/AC:L/Au:N/C:C/I:N/A:N
Weakness
CWE-306, CWE-284
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2014-9197 is a vulnerability (CVSS 10.0) in Schneider Electric Etg3000 Factorycast Hmi Gateway, published January 27, 2015. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.96%, the 80th percentile. No source names a fixed version.